Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system

نویسندگان

  • Guihong Pei
  • Liyin Zhang
چکیده

BACKGROUND Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. METHODS Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. CONCLUSIONS The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermodynamic simulation and pinch analysis of KCS11

In this study, a reputable Kalina cycle system, KCS 11, is simulated and analysed. Within this efficient cycle, there are three heat exchangers: the first heat exchanger is designated for heat absorption from the heat source, the second heat exchanger is designed for heat release to the cold source, and the third heat exchanger is designed for energy recovery. In order to achieve precise si...

متن کامل

Analysis of ground heat exchanger for a ground source heat pump: A study of an existing system to find optimal borehole length to enhance the coefficient of performance

Ground Source Heat Hump is one of the emerging technic to utilize the reservoir of geothermal energy in Europe. The crucial factor is to find the optimal length of the borehole to successfully design a heating system. The length of the borehole varies depending on the geographical area, the capacity of the heat pump and heat load of the desired building in consideration. Several methods have be...

متن کامل

Development of a Ground Source Heat Pump System with Ground Heat Exchanger Utilizing the Cast-in-place Concrete Pile Foundations of Buildings

Ground-source heat pump (GSHP) systems can achieve a higher coefficient of performance than conventional airsource heat pump (ASHP) systems because the ground, which functions as the heat source or sink, is at a higher temperature in winter and lower in summer than the air temperature (Kavanaugh 1992; Kavanaugh et al 1997). In addition, there will likely be some mitigation against the effects o...

متن کامل

Study And Experimental Analysis Of Horizontal Ground Source Heat Pump System

1Thermal Engineering, IES College of Tech. Bhopal, Madhya Pradesh, India. 2Assistant Professor, Dept. of Mechanical Eng., IES College of Tech. Bhopal, Madhya Pradesh, India. ---------------------------------------------------------------------***--------------------------------------------------------------------Abstract In modern life as we seen that the requirement of space heating and coolin...

متن کامل

Influence of Ground Heat Exchanger Modelling on the Predicted Efficiency of the Heat Pump System

This paper presents simulations of the integral coefficients of performance of a heat pump system coupled with a vertical ground heat exchanger (GHE). The GHE is simulated using different assumptions concerning the heat transfer in the ground, heat exchange between the ground and the brine and vertical variation of the brine temperature. The differences in the predicted performance coefficients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016