Use of intraoperative epiaortic ultrasonography to delineate aortic atheroma.
نویسندگان
چکیده
OBJECTIVE A cerebrovascular accident (CVA) is a devastating complication of coronary artery bypass grafting (CABG) and a major cause for morbidity and mortality. Aortic manipulation, cannulation, and clamping during CABG may lead to release of atheromatous material from the ascending aorta, which may cause a CVA. This study assessed the hypothesis that the use of intraoperative epiaortic ultrasonography (EAUS) would supplement imaging information with that derived from manual aortic palpation and influence the surgical decision-making approach accordingly. METHODS After undergoing a mid-sternotomy for CABG, 105 patients underwent EAUS with an 8-MHz transducer ordinarily used for conventional transthoracic echocardiography. The surgical strategy was decided on at three stages: preoperatively, after manual aortic palpation, and following EAUS. RESULTS The preoperative strategy had assigned 105 patients to the "touched aorta" group that was planned for either on-pump or off-pump CABG (OPCAB) with proximal anastomosis to the aorta. Pathologic lesions of the atheromatotic ascending aorta were evident in 40 patients (38%), with the lesions detected in 22 patients (21%) by both palpation and EAUS, and in 18 patients (17%) by EAUS alone. The planned surgical strategy was changed in 29 patients (28%): 25 patients (24%) were converted from on-pump CABG to OPCAB, and the EAUS influenced the choice of the aortic cannulation, cross-clamping, and proximal anastomosis site in 4 patients (4%). Among the changes in surgical decision making, changes in 11 patients (10%) were based on lesion detection by both manual palpation and EAUS; in 18 patients (17%), changes resulted from pathologic evidence provided by EAUS alone. CONCLUSIONS This study showed EAUS to be more sensitive in detecting atherosclerotic lesions than manual intraoperative palpation of the ascending aorta. This investigation contributes new data on the effect of EAUS on intraoperative surgical approach in the era of OPCAB. The use of EAUS has emerged as an important tool in intraoperative decision making, and we recommend its use routinely in CABG procedures.
منابع مشابه
Intraoperative Epiaortic Ultrasound for Traumatic Pseudoaneurysm of the Ascending Aorta.
Epiaortic ultrasound is an imaging modality that is commonly used to evaluate the ascending aorta for atheroma and other mural lesions during elective cardiac surgery. Its use in contained aortic rupture has not been established. We present a case of thoracic trauma with contained pseudoaneurysm of the ascending aorta. At operation, the precise location of the aortic tear could not be identifie...
متن کاملThe use of intraoperative epiaortic ultrasonography in monitoring patients over 75 years old treated with aortic valve replacement
INTRODUCTION Epiaortic ultrasound scanning (EAS) extended the use of ultrasound to the intraoperative diagnosis of aortic pathology. Surgical palpation of the ascending aorta underestimates the presence and severity of atherosclerotic plaques. Epiaortic ultrasound scanning has been used as an adjunct to transesophageal echocardiography (TEE) or as a primary direct diagnostic tool for imaging th...
متن کاملA standardised intraoperative ultrasound examination of the aorta and proximal coronary arteries.
The aim of this study was to describe a standardised intraoperative ultrasound examination of the aorta and proximal coronary arteries for use in cardiac surgery using a handheld probe, to be used in conjunction with intraoperative transoesophageal echocardiography. Most cardiac surgery operations involving the use of cardiopulmonary bypass will result in significant manipulation of the ascendi...
متن کاملAortic valve replacement within an unexpected porcelain aorta: the sutureless valve option.
Four patients referred for surgical treatment of aortic stenosis presented an unexpected extremely calcified (porcelain) ascending aorta at the intraoperative epiaortic ultrasonography scanning. In each patient, replacement of the aortic valve was successfully performed using a sutureless implantable bioprosthesis during a short period of hypothermic circulatory arrest. In the era of transcathe...
متن کاملEpiaortic Ultrasound Assessment of the Thoracic Aorta in Cardiac Surgery
A considerable burden of cerebral embolism in association with cardiac surgery reflects dislodgement of aortic atheroma caused by manipulating the aorta during a surgical procedure (Barbut and Gold 1996; Van Zaane, Zuithoff et al. 2008; Whitley and Glas 2008; Yamaguchi, Adachi et al. 2009). It clearly makes logical sense to identify and attempt to avoid dislodgement of aortic atheroma. This str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 127 1 شماره
صفحات -
تاریخ انتشار 2005