Reliability and current-adaptability studies of a 352 MHz, 17 MeV, continuous-wave injector for an accelerator-driven system
نویسندگان
چکیده
EUROTRANS is a European research program for the transmutation of high level nuclear waste in an accelerator-driven system (ADS). As proposed, the driver linac needs to deliver a 2.5–4 mA, 600 MeV continuous-wave (CW) proton beam and later a 20 mA, 800 MeV one to the spallation target in the prototype-scale and industrial-scale demonstration phases, respectively. This paper is focusing on the conceptual studies performed with respect to the 17 MeV injector. First, the special beam dynamics strategies and methods, which have been developed and applied to design a current-variable injector up to 30 mA for allowing an easy upgrade without additional R&D costs, will be introduced. Then the error study made for evaluating the tolerance limits of the designed injector will be presented as well.
منابع مشابه
Development of superconducting crossbar-H-mode cavities for proton and ion accelerators
The crossbar-H-mode (CH) structure is the first superconducting multicell drift tube cavity for the low and medium energy range operated in the H21 mode. Because of the large energy gain per cavity, which leads to high real estate gradients, it is an excellent candidate for the efficient acceleration in high power proton and ion accelerators with fixed velocity profile. A prototype cavity has b...
متن کاملGeometrical optimisation of the 70 mA, 70 MeV CH-Proton Injector Cavity for the FAIR Project
The FAIR project needs a new injector for the SIS-12, namely a 352 MHz CH proton linac with an output energy of 70 MeV and a beam current of 70 mA[1]. The single cell geometry has been investigated extensively in order to improve the electrical and mechanical properties at the low energy side. A cell geometry with a length of 40 mm (equivalent to β=0.09) was chosen and studied with the program ...
متن کاملThe IFUSP Microtron - Status and Perspectives
The Laboratório do Acelerador Linear (LAL) of the Physics Institute of the University of São Paulo (IFUSP) is building a 31 MeV continuous wave (cw) racetrack microtron [1][2]. This two-stage microtron comprises a 1.8 MeV injector linac, a five-turn microtron booster that increases the energy to 4.9 MeV, and the main microtron, which delivers a 31 MeV cw electron beam after 28 turns. The inject...
متن کاملمعرفی پروژه طراحی و ساخت شتابدهنده خطی الکترون پژوهشگاه دانشهای بنیادی
One of the most commonly used types of accelerators is linear electron accelerator. There is a project is in progress in Institute for research in fundamental sciences (IPM) aiming to design and build such an accelerator. It is defined in such a way that all parts to be built in Iran as possibly as it can. In this paper, after a brief explanation of the components of an electron linear accelera...
متن کاملتطبیق پذیری باریکه -H در قسمت انرژی پایین و متوسط ماشین Linac4 در سرن
Linac4 is the near future 160 MeV H- linear accelerator of the CERN presently under construction. It will replace the present Linac2 as injector of the proton accelerator complex in CERN. The Linac4 is composed of a 45 keV ion source, a Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ), which accelerates the beam to 3 MeV, and a Medium Energy Beam Transport (MEBT), ...