Three commercial immunoradiometric "kit" assays for serum ferritin evaluated.

نویسندگان

  • C D Dunn
  • D J Boden
چکیده

We evaluated three commercially available immunoradiometric assays for serum ferritin, with particular emphasis on the statistical validity of the results. The data show that it was unusual (a) for dose/response relationships of the standards to be linear over the whole concentration range suggested by the manufacturers and (b) for dose/response relationships of test sera to parallel those of the standards. These findings cast doubt on the ability of any of the assays reliably to discriminate small differences in ferritin concentrations. Nevertheless, all three methods gave reproducible results, but this reflects technical expertise rather than accuracy of the results per se. The method based on liver ferritin as tracer detected less of the iron-binding protein than those based on spleen ferritin, despite significant cross reactivity of the two antibodies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three commercial methods for serum ferritin compared and the high-dose "hook effect" eliminated.

We evaluated four commercial kits for measuring serum ferritin, based on three techniques: immunoradiometric assay, radioimmunoassay, and enzyme immunoassay. The kits evaluated were those manufactured by Abbott Laboratories, Clinical Assays, Corning Medical, and Ramco. Two of the immunoradiometric kits showed satisfactory results with respect to sensitivity and precision; they should be useful ...

متن کامل

A comparison of eleven commercial kits for the determination of serum ferritin levels.

Eleven commercial kits for serum ferritin have been compared. Seven kits used RIA and four IRMA methodology. Seven kits used human liver ferritin, two human spleen ferritin and two undefined human ferritin as standard material. Incubation times varied between 30 minutes and 36 hours. Only four kits gave normal ranges determined with the kit in question. All values were compared with the kit in ...

متن کامل

Purification and iodination of antibody for use in an immunoradiometric assay for serum ferritin.

Antibodies were purified by affinity chromatography and radioiodinated by a conjugation method for use inthe immunoradiometric assay for serum ferritin. These procedures are simpler and more reproducible than those described earlier, and the radiolabeled preparations were usable for at least 13 weeks.

متن کامل

An immunoradiometric assay for ferritin in the serum of normal subjects and patients with iron deficiency and iron overload.

An immunoradiometric assay for human ferritin has been developed. Concentrations of ferritin in the serum of male and female controls and patients with iron deficiency and iron overload were measured.Male controls were found to have a significantly higher mean concentration of serum ferritin than females. Patients with iron deficiency had significantly lower levels than normals of either sex an...

متن کامل

Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and Thyro-SHure TSH Diagnostic Kit (Nuclear Medical Laboratories). The correlation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 7  شماره 

صفحات  -

تاریخ انتشار 1981