Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?
نویسندگان
چکیده
PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Differences between the true residual astigmatism and the anticipated residual astigmatism (keratometric error) were compared at one and three months after surgery by using a separate vector analysis to identify the keratometric method that provided the highest accuracy for astigmatism control. RESULTS The mean keratomeric error was 0.52 diopters (0.17-1.17) for the manual keratometer, 0.62 (0-1.31) for the IOL master, 0.69 (0.08-1.92) for the Pentacam, and 0.59 (0.08-0.94) for the auto keratometer. The manual keratometer was the most accurate, although there was no significant difference between the keratometers (p > 0.05). All of the keratometers achieved an average keratometric error of less than one diopter. CONCLUSIONS Manual keratometry was the most accurate of the four methods evaluated, although the other techniques were equally satisfactory in determining corneal astigmatism.
منابع مشابه
Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.
PURPOSE To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Case series. METHODS Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postop...
متن کاملProspective study of toric IOL outcomes based on the Lenstar LS 900® dual zone automated keratometer
BACKGROUND To establish clinical expectations when using the Lenstar LS 900® dual-zone automated keratometer for surgery planning of toric intraocular lenses. METHODS Fifty eyes were measured with the Lenstar LS 900® dual-zone automated keratometer . Surgical planning was performed with the data from this device and the known surgically induced astigmatism of the surgeon. Post-operative refra...
متن کاملSurgical management of astigmatism with toric intraocular lenses.
Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for ch...
متن کاملIOLMaster keratometry for the calculation of toric intraocular lens power and orientation
In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially fo...
متن کاملCorrecting Astigmatism with Acrysof Toric Lenses (SN60T3 to SN60T9) in Cataract Surgery
Purpose: The objective of this study was to evaluate the outcome of Acrysof Toric intraocular lenses (IOLs) implantation in cataract surgery for the correction of regular corneal astigmatism. Methods: Twenty eyes of 16 patients with cataract and regular corneal astigmatism of 1.00-4.00 diopter (D) underwent surgery. Depending on the amount of corneal astigmatism, an Acrysof Toric IOL of type SN...
متن کامل