High Frequency Tympanometry (1,000 Hz) for Neonates with Normal and Abnormal Transient Evoked Otoacoustic Emissions
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES This paper aimed at evaluating the characteristics of high-frequency (1,000 Hz) acoustic admittance (ya) for the neonates with transient evoked otoacoustic emissions (TEOAE) as either pass or refer group. SUBJECTS AND METHODS Using a 1,000 Hz probe tone, 297neonates (152 male, 145 female aged 0-104 days old) were evaluated. Tympanometric parameters admittance value at +200 dapa, middle ear admittance, and tympanometric peak pressure were calculated for each tympanogram. RESULTS The mean of ya was 0.9678 mmho in the TEOAE for the pass group and 0.7229 mmho in the refer group. The mean of acoustic admittance at +200 (y200) was 2.0657 in the TEOAE for the pass group and 1.7191 for the refer group. The mean of Tpp was 23/8591 in the TEOAE for the pass group and 59/7619 for the refer group. CONCLUSIONS There were significant differences in the distribution of different types of tympanograms, the mean of ya, tympanic peak pressure, and y200 between the TEOAEs for the pass and the refer groups.
منابع مشابه
High-frequency (1000 Hz) tympanometry in normal neonates.
The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Ma...
متن کاملThe relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus
Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...
متن کاملTympanometry with 226 and 1000 Hertz tone probes in infants.
UNLABELLED This study aimed at describing and analyzing tympanometric results obtained with 226 Hz and 1000 Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13...
متن کامل[Clinical application of transiently evoked otoacoustic emissions in screening for auditory dysfunction].
Transiently evoked otoacoustic emissions (TEOAE) should be used clinically as an objective and noninvasive screening test for auditory dysfunction in children. The features of TEOAE measured by "ILO88" with non linear click stimuli are discussed. The following results were obtained: 1) The normal range of a power spectrum was determined using 42 adults with normal hearing and compared with data...
متن کاملAccoustic immitance measures in infants with 226 and 1000 hz probes : correlation with otoacoustic emissions and otoscopy examination Summary
Audi ological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. Aim: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. Methods: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 3...
متن کامل