Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible
نویسندگان
چکیده
BACKGROUND The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. METHODS Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC), lateral incisor (IL), canine (Ca), first premolar (P1), second premolar (P2), first molar (M1), and second molar (M2) regions. The thickness was measured in the alveolar ridge crest (T), buccal (B1-B4), and lingual (L1-L4) alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B) and lingual sides (L) were also assessed. RESULTS The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01). On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01), and was thicker than IC, IL, P1, and P2 at B2. CONCLUSIONS Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.
منابع مشابه
A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: a clinical report.
An implant-retained overdenture retained with 2 implants placed in the anterior edentulous mandible is a simple and predictable treatment option. The fabrication and use of this prosthesis requires satisfactory interarch space for adequate denture base thickness and esthetics. This clinical report describes the use of low-profile attachments for this overdenture design to solve the problem of l...
متن کاملHybrid Prosthetic Treatment of the Edentulous Mandible with Two or Four Implants - A Literature Review
Treatment of an edentulous mandible is an important standard area of indication for implants. The aim of the present study was to discuss various aspects of this very important topic using a literature research and possibly derive a recommendation for hybrid prosthetic treatment of the edentulous mandible. Though evaluation of the literature produced a large number of publications with case his...
متن کاملThe Role of Lingual Bone Grafting in the Treatment of Displaced Edentulous Mandibular Fracture with Severe Atrophy
Introduction: Treatment of edentulous atrophic mandible with severe atrophy is a challenge based on local conditions and systemic diseases confronted by the age group affected. If bone grafting is indicated, it is often used in lateral or inferior aspects of the mandible. Case Report: A 70-year-old male with a unilateral fracture of the atrophied left mandibular body was managed by lingual bon...
متن کاملHemorrhage related to implant placement in the anterior mandible.
Implant placement in the edentulous anterior mandible is relatively considered a routine and safe procedure. The interforaminal area is the usual area in the mandible for implant placement for the support and retention of a fixed partial denture or removable overdenture. This region is also the usual donor site of bone grafts. However, implant placement, like any other surgical procedure, is no...
متن کاملIn Vitro Effect of Vent Size and Spacer Thickness on Pressure Produced during Maxillary Edentulous Impression Making by Different Impression Materials
Background and Aim: Inappropriate transfer of pressure during final impression making in fabrication of complete denture can result in ridge resorption. This study aimed to assess the effect of vent size and spacer thickness on pressure produced during maxillary edentulous impression making by different impression materials in vitro. Materials and Methods: This experimental study was carried...
متن کامل