Results of repair of iliac artery aneurysms with the sandwich technique.
نویسندگان
چکیده
Patients undergoing endovascular repair (EVAR) of aortoiliac or iliac artery aneurysm may require sacrifice of one or both internal iliac arteries (IIAs). Until Food and Drug Administration-approved commercial grafts became available, endovascular IIA preservation was accomplished using the "sandwich" technique, but limited information is available regarding the results of this method. After obtaining institutional review board approval, we identified patients undergoing IIA preservation with the sandwich technique during EVAR at our institution. The patients have been followed prospectively since being identified to record patency rates and vascular symptoms or events. Twenty-four procedures were performed from 2011 through 2015 to treat iliac artery aneurysms. Fourteen of these procedures were done with concomitant EVAR using different endografts (Gore Excluder 11, Endologix AFX 2, Cook Zenith 1). Five were done to extend a previous EVAR that had developed a type Ib endoleak, 2 for an isolated external iliac artery aneurysm, 3 for an anastomotic aneurysm from a previous aortobiiliac graft, and 2 for isolated iliac aneurysm repair. There were 25 sandwich grafts (unilateral in 19, bilateral in 6). Contralateral embolization was performed in 5 cases. Immediate success rates were high, and patency rates were excellent at intermediate follow-up. Intraoperative type 3 endoleaks were not uncommon but usually resolved postoperatively. Endovascular IIA preservation is feasible with currently available devices using this technique. This procedure is recommended for preservation of the IIA during endovascular treatment of aortoiliac and iliac artery aneurysms when anatomy requires IIA preservation.
منابع مشابه
Successful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report
Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...
متن کاملEndovascular Repair of Aortoiliac Aneurysm Using Bifurcated Stent Grafts with Sandwich Technique for Preserving the Internal Iliac Artery
In this case, we describe a case of a 76-year-old male with extensive aortoiliac aneurysms treated by endovascular aneurysm repair using the sandwich technique in order to preserve left internal iliac artery perfusion. The sandwich technique refers to the deployment of multiple paralleled stent grafts into main distal and side branches in overlapping with a single proximal stent graft. The proc...
متن کاملThe Upside-Down Gore Excluder Limb and Double-Barrel Sandwich Technique for Penetrating Aortic Ulcer and Iliac Aneurysm Exclusion
Endovascular aneurysm repair has become the first-line treatment for abdominal aortic aneurysms and iliac artery aneurysms in recent years. However, the diameter of the infrarenal aorta is larger than that of the aortic bifurcation, especially with small aortic diameters, for which a reversed tapered device is necessary. We describe the off-label use of the upside-down Gore Excluder limb and do...
متن کاملConcomitant Celiac, Superior Mesenteric, Renal, and Aorto-bi-iliac Aneurysms
Visceral artery aneurysms are rarely reported. They can occur in the context of a variety of underlying diseases. These aneurysms may coexist with non-visceral arterial aneurysms.Here we describe an 80-year-old man with concomitant superior mesenteric, celiac, renal, and aorto-bi-iliac aneurysms. The patient was a hypertensive and hyperlipidemic old man with history of transient ischemic attack...
متن کاملEarly Experiences of Sandwich Technique to Preserve Pelvic Circulation during Endovascular Aneurysm Repair
PURPOSE To report experiences of the sandwich technique (ST) for preservation of pelvic flow during endovascular repair of complex aortic or aortoiliac aneurysms. MATERIALS AND METHODS Eight patients underwent elective endovascular aneurysm repair (EVAR) using the ST between March 2013 and February 2017. The anatomic indications for the ST were complex aortoiliac aneurysms (5 cases), abdomina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2017