Method development study for APR cartridge evaluation in fire overhaul exposures.

نویسندگان

  • T Renée Anthony
  • Philip Joggerst
  • Leonard James
  • Jefferey L Burgess
  • Stephen S Leonard
  • Elizabeth S Shogren
چکیده

In the US, firefighters do not typically wear respiratory protection during overhaul activities, although fitting multi-gas or chemical, biological, radiological and nuclear cartridges to supplied air respirator facepieces has been proposed to reduce exposures. This work developed a method to evaluate the effectiveness of respirator cartridges in smoke that represents overhaul exposures to residential fires. Chamber and penetration concentrations were measured for 91 contaminants, including aldehydes, polynuclear aromatic hydrocarbons, hydrocarbons and methyl isothiocyanate, along with total and respirable particulates. These laboratory tests generated concentrations in the range of field-reported exposures from overhaul activities. With limited tests, no styrene, benzene, acrolein or particulates were detected in air filtered by the respirator cartridge, yet other compounds were detected penetrating the respirator. Because of the complexity of smoke, an exposure index was determined for challenge and filtered air to determine the relative risk of the aggregate exposure to respiratory irritants. The primary contributors to the irritant exposure index in air filtered by the respirator were formaldehyde and acetaldehyde, with total hydrocarbons contributing only 1% to the irritant index. Respirator cartridges were adequate to minimize firefighter exposures to aggregate respiratory irritants if the American Conference of Governmental Industrial Hygienists ceiling limit for formaldehyde is used (0.3 ppm) but not if National Institute for Occupational Safety and Health Recommended Exposure Limit (NIOSH REL) (0.1 ppm) is used, where three of five concentrations in filtered air exceeded the NIOSH REL. Respirator certification allows 1 ppm of formaldehyde to pass through it when challenged at 100 ppm, which may not adequately protect workers to current short-term exposure/ceiling limits. The method developed here recommends specific contaminants to measure in future work (formaldehyde, acrolein, acetaldehyde, naphthalene, benzene, total hydrocarbons as toluene and particulate mass) along with inclusion of additional irritant gases and hydrogen cyanide to fully evaluate whether air-purifying respirators reduce exposures to the aggregate gases/vapors present in overhaul activities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory protection for firefighters--evaluation of CBRN canisters for use during overhaul.

In the United States, there are approximately 366,600 structural fires each year. After visible flames are extinguished, firefighters begin the overhaul stage of firefighting to smother remaining hot spots and initiate investigations. Typically during overhaul significant ambient concentrations of chemical contaminants remain. However, previous research suggests that the use of air purifying re...

متن کامل

The evaluation of CBRN canisters for use by firefighters during overhaul.

Air-purifying respirators (APRs) have been proposed to provide an additional respiratory protection option for structural firefighters involved in overhaul operations and wildland firefighters, where particulate and aldehyde exposures have been documented. Previous studies (Anthony et al., 2007) developed test methods to evaluate APR cartridges and canisters for use in overhaul activities, wher...

متن کامل

Respiratory protection for firefighters--Evaluation of CBRN canisters for use during overhaul II: In mask analyte sampling with integrated dynamic breathing machine.

According to the National Fire Protection Association there were 487,500 structural fires in the U.S. in 2013. After visible flames are extinguished firefighters begin the overhaul stage where remaining hot spots are identified and further extinguished. During overhaul, a significant amount of potentially hazardous chemicals can remain in the ambient environment. Previous research suggests that...

متن کامل

Development of a Fire Safety Checklist for Dormitories

Background;Despite advances in technology, people are still exposed to fire hazard. Students can be one of the most important exposed groups. Therefore, fire safety inspection should be established in dormitories. The aim of this study was to develop a fire safety checklist for fire safety inspection in dormitories. Methods; This study was as a tool development followed by a cross-sectional st...

متن کامل

Optimal overhaul–replacement policy for a multi-degraded repairable system sold with warranty

In this research, we study an optimal overhaul–replacement policy of a multi-degraded repairable system sold with a free replacement warranty. In the proposed replacement policy, a maintenance action and failure are dependent on a system degradation level and the system age, and hence the replacement model will provide more effective maintenance decisions. Failure of the system is modeled using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 51 8  شماره 

صفحات  -

تاریخ انتشار 2007