Is grid therapy useful for all tumors and every grid block design?
نویسندگان
چکیده
Grid therapy is a treatment technique that has been introduced for patients with advanced bulky tumors. The purpose of this study is to investigate the effect of the radiation sensitivity of the tumors and the design of the grid blocks on the clinical response of grid therapy. The Monte Carlo simulation technique is used to determine the dose distribution through a grid block that was used for a Varian 2100C linear accelerator. From the simulated dose profiles, the therapeutic ratio (TR) and the equivalent uniform dose (EUD) for different types of tumors with respect to their radiation sensitivities were calculated. These calculations were performed using the linear quadratic (LQ) and the Hug-Kellerer (H-K) models. The results of these calculations have been validated by comparison with the clinical responses of 232 patients from different publications, who were treated with grid therapy. These published results for different tumor types were used to examine the correlation between tumor radiosensitivity and the clinical response of grid therapy. Moreover, the influence of grid design on their clinical responses was investigated by using Monte Carlo simulations of grid blocks with different hole diameters and different center-to-center spacing. The results of the theoretical models and clinical data indicated higher clinical responses for the grid therapy on the patients with more radioresistant tumors. The differences between TR values for radioresistant cells and radiosensitive cells at 20 Gy and 10 Gy doses were up to 50% and 30%, respectively. Interestingly, the differences between the TR values with LQ model and H-K model were less than 4%. Moreover, the results from the Monte Carlo studies showed that grid blocks with a hole diameters of 1.0 cm and 1.25 cm may lead to about 19% higher TR relative to the grids with hole diameters smaller than 1.0 cm or larger than 1.25 cm (with 95% confidence interval). In sum-mary, the results of this study indicate that grid therapy is more effective for tumors with radioresistant characteristics than radiosensitive tumors.
منابع مشابه
Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes
Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...
متن کاملGrid: A location dependent intensity modulated radiotherapy for bulky tumors
Background: An effective method for management of large and bulky malignant tumors. This treatment modality is also known as Specially Fractionated Radiation Therapy (SFRT). In this treatment technique a grid block converted the open radiation field into a series of pencil beams. Dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and Mo...
متن کاملDose GRID increase the unwanted photoneutron dose to the patients in GRID therapy?
Introduction: GRID therapy is a treatment modality in which a high dose of radiation in a single fraction is given to the tumor. This technique previously was used to treat bulky tumors with orthovoltage beams. Recently, studies have been conducted to suggest that GRID therapy with megavoltage photons can be useful in palliative treatments. On the other hand, there has always ...
متن کاملRadiation-induced bystander effect following hypo- fraction technique of grid therapy by use of sensitive molecular markers
Introduction: Radiation-induced bystander effect (RIBE) is a well-known response associated with the induction of radiation effects in non-irradiated cells via signaling of hit ones. As this so-called phenomenon has been largely investigated in low dose levels, few studies focused on higher dose levels such as grid therapy. Grid therapy or spatially fractionated gri...
متن کاملDesign and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller
In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...
متن کامل