Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings.
نویسندگان
چکیده
INTRODUCTION After endodontic surgery, radiographic assessment is the method of choice to monitor bone defect healing. Cone-beam computed tomography scans are useful to check and identify the reasons of failure of surgical intervention or confirm healing; however, the artifact generated by some root-end filling material might compromise this task. The objective of the study was to compare the amount of artifacts generated by 4 root-end filling materials and to test multiple exposure settings used with these materials, when the effective dose generated by each protocol was taken into consideration. METHODS Twenty central incisors were endodontically treated with retrograde obturation by using amalgam, Biodentine, MTA, and Super-EBA (5 of each). They were placed in a skull with soft tissue simulation and scanned by using the Planmeca Promax Max with different kilovolt peaks (kVp): 66, 76, 84, and 96 with and without the use of metal artifact reduction (MAR) algorithm and with low, normal, and high resolution and high definition. The Dose Area Product was registered, and the effective dose was calculated. RESULTS Amalgam generated the highest amount of artifacts, whereas MAR and low resolution created fewer artifacts than other settings. The artifacts were also reduced with 96 kVp. The effective dose calculated with low resolution was remarkably lower than other resolutions. CONCLUSIONS When used as root-end filling material, Biodentine, MTA, and Super-EBA generated fewer artifacts than amalgam. The use of 96 kVp with MAR and low resolution also reduced artifacts on the image and at the same time generated the lowest effective dose.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملEvaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملDiagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts
Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...
متن کاملEvaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines
Introduction: Maxillary canines have important roles in facial appearance, development of arch, and functional occlusion. Radiographs are important in evaluating the location and nature of these anomalies. The purpose of this study was to evaluate two types of 2D and 3D imaging technique in diagnosis and treatment of maxillary impacted canines. Methods: Thirty eight patients (50 impacted canine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 42 2 شماره
صفحات -
تاریخ انتشار 2016