Kinematics of total facet replacement (TFAS-TL) with total disc replacement

نویسندگان

  • Leonard I. Voronov
  • Robert M. Havey
  • Simon G. Sjovold
  • Michael Funk
  • Gerard Carandang
  • Daniel Zindrick
  • David M. Rosler
  • Avinash G. Patwardhan
چکیده

BACKGROUND Total disc replacement (TDR) and total facet replacement (TFR) have been the focus of recent kinematics evaluations. Yet their concurrent function as a total joint replacement of the lumbar spine's 3-joint complex has not been comprehensively reported. This study evaluated the effect of a TFR specifically designed to replace the natural facets and supplement the function with the natural disc and with TDR. The ability to replace degenerated facets to complement a pre-existing or simultaneously implanted TDR may allow surgeons to completely address degenerative pathologies of the 3-joint complex of the lumbar spine. We hypothesized that TFR would reproduce the biomechanical function of the natural facets when implanted in conjunction with TDR. METHODS Lumbar spines (L1-5, 51.3 ± 14.2 years, N = 6) were tested sequentially as follows: (1) intact, (2) after TDR implantation, and (3) after TFR implantation in conjunction with TDR, all at L3-4. Specimens were tested in flexion-extension (+ 8 Nm to - 6 Nm), lateral bending (± 6 Nm), and axial rotation (± 5 Nm). A 400 N compressive follower preload was applied during flexion-extension tests. Three-dimensional segmental motion was recorded and analyzed using analysis of variance in Systat (Systat Software Inc., Chicago, Illinois) and multiple comparisons with Bonferroni correction. RESULTS The TDR implantation (TDR + natural facets) allowed similar lateral bending (P = .66), but it generally increased flexion-extension (P = .06) and axial rotation (P < .05) range of motion (ROM) at the implanted level compared to intact. The TFR + TDR (following replacement of the natural facets with TFR) decreased ROM to levels similar to intact in lateral bending (P = .70) and axial rotation (P = .23). The TFR + TDR flexion-extension ROM was reduced in comparison to intact and TDR + natural facets (P < .05). CONCLUSIONS The TFR with TDR was able to restore stability to the lumbar segment after bilateral facetectomy, while allowing near-normal motions in all planes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stem fracture after total facet replacement in the lumbar spine: a report of two cases and review of the literature.

BACKGROUND CONTEXT A randomized controlled multicenter investigational device exemption clinical trial comparing the total facet arthroplasty system (TFAS) (Archus Orthopedics, Redmond, WA, USA) with posterior fusion was discontinued because of financial reasons. To our knowledge, no clinical outcomes or complications have yet been presented for the TFAS, and no device-related complications hav...

متن کامل

L5 – S1 Segmental Kinematics After Facet Arthroplasty

BACKGROUND Facet arthroplasty is a motion restoring procedure. It is normally suggested as an alternative to rigid fixation after destabilizing decompression procedures in the posterior lumbar spine. While previous studies have reported successful results in reproducing normal spine kinematics after facet replacement at L4-5 and L3-4, there are no data on the viability of facet replacement at t...

متن کامل

A historical review and current perspective on the intervertebral disc prosthesis.

Spinal fusion for degenerative disc disease has been associated with a variety of side effects, including increased morbidity, infection, failed back syndrome, pseudoarthrosis, and acceleration of degenerative changes in adjacent intervertebral discs and facet joints. Based on the experience of arthroplasty of hip and other joints, there has been an escalating in research emphasizing the design...

متن کامل

Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.

In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation software applied to CT scans before and aft...

متن کامل

Implications of Artificial Disc Design on the Intersegmental Biomechanics of the Lumbar Spine

INTRODUCTION: Design of total disc replacement (TDR) prosthesis plays an important role in the long-term clinical performance of these implants. Prodisc-L (Spine Solutions, Inc. Synthes, Paoli, PA, USA), a semi-constrained TDR system, has a ball-and-socket based design; whereas SB Charité III (DePuy Spine, Inc, Raynham, MA, USA) has a theoretically unconstrained articulation which allows the mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009