X-Treme beamline at SLS: X-ray magnetic circular and linear dichroism at high field and low temperature.

نویسندگان

  • Cinthia Piamonteze
  • Uwe Flechsig
  • Stefano Rusponi
  • Jan Dreiser
  • Jakoba Heidler
  • Marcus Schmidt
  • Reto Wetter
  • Marco Calvi
  • Thomas Schmidt
  • Helena Pruchova
  • Juraj Krempasky
  • Christoph Quitmann
  • Harald Brune
  • Frithjof Nolting
چکیده

X-Treme is a soft X-ray beamline recently built in the Swiss Light Source at the Paul Scherrer Institut in collaboration with École Polytechnique Fédérale de Lausanne. The beamline is dedicated to polarization-dependent X-ray absorption spectroscopy at high magnetic fields and low temperature. The source is an elliptically polarizing undulator. The end-station has a superconducting 7 T-2 T vector magnet, with sample temperature down to 2 K and is equipped with an in situ sample preparation system for surface science. The beamline commissioning measurements, which show a resolving power of 8000 and a maximum flux at the sample of 4.7 × 10(12) photons s(-1), are presented. Scientific examples showing X-ray magnetic circular and X-ray magnetic linear dichroism measurements are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The high-field magnet endstation for X-ray magnetic dichroism experiments at ESRF soft X-ray beamline ID32

A new high-field magnet endstation for X-ray magnetic dichroism experiments has been installed and commissioned at the ESRF soft X-ray beamline ID32. The magnet consists of two split-pairs of superconducting coils which can generate up to 9 T along the beam and up to 4 T orthogonal to the beam. It is connected to a cluster of ultra-high-vacuum chambers that offer a comprehensive set of surface ...

متن کامل

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism (XMCD) on the bending-magnet beamline BM25A (SpLine) at the ESRF. Field reversal and helicity reversal techniques have been used to carry out the measurements. The performance of the experimental set-up h...

متن کامل

A hard X-ray nanospectroscopy station at SPring-8 BL39XU

We upgraded the hard X-ray spectroscopy beamline BL39XU at SPring-8 by installing Kirkpatrick-Baez mirrors to equip it with submicron-focusing capability. At the new experimental end-station located 74 m from the undulator source, an X-ray nanoprobe with a size of 120 × 100 nm has become available at 5–16 keV. This upgrade is fully compatible with the X-ray polarization tunability and helicity-...

متن کامل

XMCD under pressure at the Fe K edge on the energy-dispersive beamline of the ESRF.

The present paper demonstrates the feasibility of X-ray absorption spectroscopy (XAS) and X-ray magnetic circular dichroism (XMCD) at high pressure at the Fe K edge on the ID24 energy-dispersive beamline of the ESRF. In 3d transition metals, performing experiments at the hard X-ray K edge rather than at the magnetically interesting soft X-ray L edges represents the only way to access the high-p...

متن کامل

An ultrafast x-ray detector system at an elliptically polarizing undulator beamline

An ultrafast x-ray detector system is under development at Lawrence Berkeley National Laboratory (LBNL) for application primarily to study of ultrafast magnetization dynamics. The system consists of a fs laser, an x-ray streak camera and an elliptically polarization undulator (EPU) beamline. Polarized x-rays from an EPU can be used to measure x-ray magnetic circular dichroism (XMCD) of a sample...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 19 Pt 5  شماره 

صفحات  -

تاریخ انتشار 2012