An intracardiac manometer: its evaluation and application.

نویسندگان

  • E J ELLIS
  • O H GAUER
  • E H WOOD
چکیده

The miniature intracardiac manometer supplied a method for recording artefact-free pressure tracings from the heart and great vessels of man and the intact animal. This instrument has been applied to the procedure of cardiac catheterization. It has also been used to demonstrate that if motion artefacts can be minimized, the central pulse can be recorded with reasonable accuracy by means of manometric systems with relatively poor dynamic response. Illustrations of pulse waves within the heart and great vessels of man and dogs and the effects of varying the dynamic response of the recording system are included. T HE WIDESPREAD acceptance and application of cardiac catheterization in diagnosis of congenital heart disease has required the accurate recording of changes in intracardiac pressure. In spite of the physical difficulties of recording through a long, narrow-bore cardiac catheter, it has been found that manometer-catheter systems with reasonably adequate dynamic response can be evolved.'-' Even when such manometer-catheter systems are used, the recordings of pressure obtained from the right ventricle and pulmonary artery of human beings are often obviously distorted by artefacts.' 2 The artefacts are, for the most part, produced by pressures generated in the lumen of the catheter by the acceleration and deceleration of the contained column of fluid, associated with movements of the catheter imparted by the heart beat.1' 2 This type of motion artefact can be minimized if the movable mass coupled to the manometer is very small so that the reactive forces and consequent pressures generated by movement are correspondingly reduced. A manometer made sufficiently small to be attached to the intracardiac end of a cardiac catheter would have this characteristic. It would also avoid other serious difficulties associated with recording through a long narrow plastic tube, such as damping factors, entrapped air bubbles and variation of physical characteristics of the catheter which accompany change of temperature. Gauer and Gienapp" 5 designed such an instrument according to the principles first outlined by Wetterer.6 The manometer as applied in cardiac catheterization is illustrated in figure 1. The brass housing of the miniature manome-ter accommodates two transformers, the secondary coils of which are wound in opposite directions. The relative coupling of the coils varies with the movements of a soft iron core mounted on the base of a tiny piston which is pressurized by the intracardiac or vascular pressure. The manometer is attached to an 8 F. cardiac catheter and projects …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Method for the Study of the Intracardiac Pressure Curve

THE method about to be described secures a correct record of any part of the intracardiac pressure curve, for it meets the theoret-Fig. 1.-Scheme illustrating the arrangement of the apparatus. The meaning of the abbreviations is given in the text. ieal requirements of a perfect method, in that it employs an incom-pressible fluid and at the same time practically does away with the inertia error....

متن کامل

Sensitivity of transcranial Doppler versus intracardiac echocardiography in the detection of right-to-left shunt.

OBJECTIVES The purpose of this study was to understand the reason for variation in the sensitivity of different methods of detecting right-to-left shunts (RLS). BACKGROUND Patent foramen ovale (PFO) is implicated in the pathogenesis of cryptogenic stroke, decompression illness, and migraine headaches. Intravenous agitated saline injections with tomographic imaging (transthoracic, transesophag...

متن کامل

Heart Sounds and Pressures in Atrial Septal Defect.

The existence of a large communication between the atria allows detailed study of sounds and pressures in the four heart chambers and the pulmonary arteries. Only the aorta is inaccessible to the cardiac catheter. In uncomplicated atrial septal defect, moreover, pressures within the heart chambers are almost normal. There are no important pressure gradients across the valves. It seems likely, t...

متن کامل

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Intracardiac Thrombus in Renovascular Hypertension: A Case Report

Thromboembolism is a rare complication of primary nephortic syndrome. Both venous and arterial thrombosis might occur in steroid responsive and steroid resistant nephrotic syndrome. This is the report of an infant with nephrotic syndrome and renovascular hypertension, complicated with asymptomatic intracardiac thrombus and managed appropriately with medical treatment.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 1951