A 3.5-mm-diameter anterior cruciate ligament tibial retrograde socket drilling pin is more accurate than a 2.4-mm-diameter pin.
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate the accuracy of a 3.5-mm-diameter anterior cruciate ligament (ACL) tibial retrograde socket drilling pin versus a standard, 2.4-mm drill-tipped guide pin. A secondary purpose was to evaluate surgeon precision in identifying the true (anatomic) center of the ACL tibial footprint using arthroscopic visualization. METHODS Six matched pairs of cadaveric knees were disarticulated, leaving a well-defined footprint of the ACL on the tibial plateau. The tibial footprint was digitally recorded by a bioengineer, and the true center of the footprint was calculated. Next, using arthroscopic visualization, a surgeon identified and marked his estimation of the true center of the ACL tibial footprint. This mark was then digitally recorded by the bioengineer and compared with the calculated center, allowing quantification of surgeon anatomic precision. Finally, under arthroscopic visualization, the surgeon was given 1 attempt to aim and drill the guide pin to his mark. Pin position was digitally recorded; the distance of the drill pin from the mark quantified drill pin placement accuracy. RESULTS Mean accuracy for the 3.5-mm retrograde socket drilling pin was 1.06 ± 0.75 mm versus 3.03 ± 1.00 mm for the 2.4-mm pin. The difference was significant (P < .005). Surgeon anatomic precision was 2.7 ± 1.4 mm. CONCLUSIONS Our results show that a 3.5-mm-diameter ACL tibial retrograde socket drilling pin is significantly more accurate than a 2.4-mm-diameter pin. The 3.5-mm pin accuracy is within the range of surgeon precision; the 2.4-mm pin accuracy is not. CLINICAL RELEVANCE Pin accuracy and surgeon precision are clinically relevant measures because anatomic tunnel placement is a determinant of ACL reconstruction outcome.
منابع مشابه
Drill wobble – effect on femoral tunnel aperture during anterior cruciate ligament reconstruction
BACKGROUND In anterior cruciate ligament reconstruction performed using cortical button fixation on the femur, we have observed a "wobble" effect that can occur when a cannulated femoral drill is used over a guide pin that is not securely fixed in bone. Our study assessed the effect of drill "wobble" on femoral tunnel aperture in sawbones. METHODS Femoral tunnels were drilled in sawbones, whi...
متن کاملTechnical note: Anterior cruciate ligament reconstruction in the presence of an intramedullary femoral nail using anteromedial drilling
AIM To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. METHODS Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic a...
متن کاملPosterior Cruciate Ligament Reconstruction with Retrograde Femoral Technique, Posterior Trans-septal Portal and Full Tibial Tunnel
Suspensory femoral graft fixation has been a popular and reliable method in anterior cruciate ligament (ACL) reconstruction. Some authors have introduced suspensory femoral fixation in posterior cruciate ligament (PCL) reconstruction using inside-out (IO) technique. The use of IO technique for femoral tunnel preparation could significantly sharpen the critical corner, which might result in graf...
متن کاملTibial Tunnel Preparation in Posterior Cruciate Ligament (PCL) Reconstruction. A Technical Tip to Lessen the Stress
Background: The purpose of this study was to introduce a technical tip for the preparation of tibial tunnel in a posteriorcruciate ligament (PCL) reconstruction to reduce the chance of popliteal artery injury and duration of the surgery.Methods: This study included 18 patients who underwent PCL reconstructions at Imam Khomeini University Hospital,Tehran, Iran, between 2016 and...
متن کاملTranstibial versus anteromedial portal reaming in anterior cruciate ligament reconstruction: an anatomic and biomechanical evaluation of surgical technique.
PURPOSE The purpose of this study was to objectively evaluate the anatomic and biomechanical outcomes of anterior cruciate ligament (ACL) reconstruction with transtibial versus anteromedial portal drilling of the femoral tunnel. METHODS Ten human cadaveric knees (5 matched pairs) without ligament injury or pre-existing arthritis underwent ACL reconstruction by either a transtibial or anterome...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 27 5 شماره
صفحات -
تاریخ انتشار 2011