High resolution multislice imaging of the fetal heart using iGRASP and MOG
نویسندگان
چکیده
Background Multi-slice CINE MRI is an integral facet of postnatal cardiac examinations, but its application to the fetal heart is hampered by the lack of a fetal cardiac gating signal and the possibility of fetal motion. In this work, a method for reconstructing high spatial and temporal resolution multi-slice images of the fetal heart in a clinically acceptable scan time is presented. The proposed method combines metric optimized gating (MOG), a solution for fetal cardiac gating, with golden-angle radial sparse parallel MRI (iGRASP), a motion-robust acquisition and reconstruction scheme for highly undersampled data acquisitions [1,2].
منابع مشابه
Dynamic MRI of the fetal myocardium
Background Fetal cardiovascular MRI has been hampered by the lack of a reliable cardiac gating signal. A recently proposed solution to this problem is metric optimized gating (MOG) [1-3]. Here, we demonstrate the ability of MOG to acquire images of the fetal myocardium without conventional cardiac gating. Our work is motivated by the need for high-resolution dynamic imaging in the assessment of...
متن کاملAccelerated phase contrast measurements of fetal blood flow using compressed sensing
Background Phase contrast (PC) MR is routinely used to quantify blood flow in postnatal subjects and through the use of metric optimized gating (MOG) has been employed in studies of fetal blood flow in both normal pregnancies and fetal congenital heart disease [1-3]. Still, the scan time required for high resolution fetal PCMR remains a practical limitation. Recently, compressed sensing (CS) ha...
متن کاملDynamic imaging of the fetal heart using metric optimized gating.
PURPOSE Advances in fetal cardiovascular magnetic resonance imaging have been limited by the absence of a reliable cardiac gating signal. The purpose of this work was to develop and validate metric-optimized gating (MOG) for cine imaging of the fetal heart. THEORY AND METHODS Cine MR and electrocardiogram data were acquired in healthy adult volunteers for validation of the MOG method. Compari...
متن کاملمقایسه دوز پرتویی و کیفیت تصویر توموگرافی کامپیوتری مولتی اسلایس (MSCT) معمولی، توموگرافی کامپیوتری پرتو مخروطی (CBCT) و رادیوگرافی پری اپیکال در تصویربرداری دندانپزشکی
Background and Aims: With the increasing use of CT (Computed Tomoghraphy) scans in dentistry especially in the implantology, there may be significant increases in the radiation exposure and its risk. During the last year’s ConeBeam Computed Tomoghraphy (CBCT) has been introduced as an imaging modality for dentistry. The aim of this review article was to present comprehensive inform...
متن کاملGolden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI.
PURPOSE To develop a fast and flexible free-breathing dynamic volumetric MRI technique, iterative Golden-angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden-angle radial sampling. METHODS Radial k-space data are acquired continuously using the golden-angle scheme and sorted into time series by grouping an arbitrary number of consecutive sp...