Evaluation of linear array human papillomavirus genotyping using automatic optical imaging software.

نویسندگان

  • J Jeronimo
  • N Wentzensen
  • R Long
  • M Schiffman
  • S T Dunn
  • R A Allen
  • J L Walker
  • M A Gold
  • R E Zuna
  • M E Sherman
  • S Wacholder
  • S S Wang
چکیده

Variations in biological behavior suggest that each carcinogenic human papillomavirus (HPV) type should be considered individually in etiologic studies. HPV genotyping assays might have clinical applications if they are approved for use by the FDA. A widely used genotyping assay is the Roche Linear Array HPV genotyping test (LA). We used LA to genotype the HPV isolates from cervical specimens from women with the full spectrum of cervical disease: cervical cancer, cervical intraepithelial neoplasia (CIN), and HPV infections. To explore the feasibility and value of the automated reading of the LA results, we custom-designed novel, optical imaging software that provides optical density measurements of LA bands. We compared unmagnified visual examination with the automated measurements. The two measurements were highly associated. By either method, the threshold between a negative and a positive result was fairly sharp, with a clear bimodal distribution. Visually, most positive results were judged to be strong or medium, with fewer equivocal results categorized as weak (9.5% of positive samples), very weak (6.5% of positive samples), or extremely weak (7.7% of positive samples). The automated measurements of the intensities were significantly associated with the strength of the visual categories (P < 0.001). At the extremes of the automated signal intensities (< or = 20 units or > or = 120 units), the bands were almost always categorized visually as negative and positive, respectively. In the equivocal zone (20 to 119 units), specimens were more increasingly likely to be judged to be visually positive as the number of other, definite infections on the same strip increased (P for trend < 0.001). Multiple, concurrent infections comprise > or = 25% of HPV infections; thus, any systematic visual tendency that influences their evaluation when the result is equivocal should be minimized. Therefore, automated reading is probably worth development if easy-to-calibrate hardware and software can be optimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Comparison of real-time multiplex human papillomavirus (HPV) PCR assays with the linear array HPV genotyping PCR assay and influence of DNA extraction method on HPV detection.

Real-time human papillomavirus (HPV) type-specific multiplex PCR assays were developed to detect HPV DNA in specimens collected for the efficacy determination of the quadrivalent HPV (type 6, 11, 16, and 18) L1 virus-like particle (VLP) vaccine (Gardasil). We evaluated the concordance between type-specific multiplex HPV PCR and the widely used, commercially available Roche Linear Array genotypi...

متن کامل

Comparison of DNA sequencing and Roche Linear array in human papillomavirus (HPV) genotyping.

BACKGROUND Human papillomavirus (HPV) is the etiological agent of cervical cancer. HPV genotyping is important to determine the presence of high-risk types. Recently, a new HPV genotyping method, the Roche Linear array genotyping test, was introduced and is compared here with a sequencing-based HPV genotyping system. MATERIALS AND METHODS A series of 102 women (age range 30-55 years) shown to...

متن کامل

Evaluation of the SPF10-INNO LiPA human papillomavirus (HPV) genotyping test and the roche linear array HPV genotyping test.

The need for accurate genotyping of human papillomavirus (HPV) infections is becoming increasingly important, since (i) the oncogenic potential among the high-risk HPV genotypes varies in the pathogenesis of cervical cancer, (ii) monitoring multivalent HPV vaccines is essential to investigate the efficiency of the vaccines, and (iii) genotyping is crucial in epidemiologic studies evaluating HPV...

متن کامل

Comparison of the DiagCor GenoFlow Human Papillomavirus Array Test and Roche Linear Array HPV Genotyping Test

Persistent infection of high-risk (HR) human papillomavirus (HPV) infection has been widely associated with cervical cancer. Monitoring HPV infection is therefore an important step against cervical cancer development. The DiagCor GenoFlow Human Papillomavirus Array Test (GenoFlow) is a novel HPV test based on PCR and "Flow-through" hybridization that can identify 33 HPV subtypes in 3 hours. In ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 46 8  شماره 

صفحات  -

تاریخ انتشار 2008