Wireless Accelerometer for Neonatal MRI Motion Artifact Correction
نویسندگان
چکیده
A wireless accelerometer has been used in conjunction with a dedicated 3T neonatal MRI system installed on a Neonatal Intensive Care Unit to measure in-plane rotation which is a common problem with neonatal MRI. Rotational data has been acquired in real-time from phantoms simultaneously with MR images which shows that the wireless accelerometer can be used in close proximity to the MR system. No artifacts were observed on the MR images from the accelerometer or from the MR system on the accelerometer output. Initial attempts to correct the raw data using the measured rotational angles have been performed, but further work will be required to make a robust correction algorithm.
منابع مشابه
POCS-Enhanced Parallel MRI Correction of MR Image Artifacts
A. Samsonov, E. Kholmovski, C. Johnson Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, United States, Department of Radiology, University of Wisconsin, Madison, Wisconsin, United States, UCAIR, University of Utah, Salt Lake City, Utah, United States, Scientific Computing and Imaging Institute, University of Utah, University of Utah, Salt Lake City, Utah, United State...
متن کاملCancellation due to Rigid Motion in the Imaging Plane 1 Reza
A post-processing technique has been developed to suppress the MRI artifact arising from object planar rigid motion. In 2-DFT MRI, rotational and translational motions of the target during MR scan respectively impose non-uniform sampling and a phase error on the collected MRI signal. The artifact correction method introduced considers the following three conditions: (i) For planar rigid motion ...
متن کاملPOCS-enhanced correction of motion artifacts in parallel MRI.
A new method for correction of MRI motion artifacts induced by corrupted k-space data, acquired by multiple receiver coils such as phased arrays, is presented. In our approach, a projections onto convex sets (POCS)-based method for reconstruction of sensitivity encoded MRI data (POCSENSE) is employed to identify corrupted k-space samples. After the erroneous data are discarded from the dataset,...
متن کاملInter-slice motion correction using spatiotemporal interpolation for functional magnetic resonance imaging of the moving fetus
Fetal motion continues to be one of the major artifacts in in-utero functional MRI; interestingly few methods have been developed to address fetal motion correction. In this study, we propose a robust method for motion correction in fetal fMRI by which both inter-slice and inter-volume motion artifacts are jointly corrected. To accomplish this, an original volume is temporally split into odd an...
متن کاملPolitecnico Di Torino Porto Institutional Repository [proceeding] Motion Artifact Correction in Asl Images: an Improved Automated Procedure Motion Artifact Correction in Asl Images: an Improved Automated Procedure
Arterial Spin Labelling (ASL) is a perfusion MRI technique with tremendous applications in the study of biological markers and prognostic factors of brain tumors and in the assessment of neural diseases; moreover, it is completely non-invasive as it uses the magnetically inverted blood of the patient as an endogenous tracer. Unfortunately this powerful method is only viable in very limited cond...
متن کامل