Erythrocyte-magnetized technology: an original and innovative method for blood group serology.
نویسندگان
چکیده
BACKGROUND Erythrocyte-magnetized technology (EMT) is a new fully automated method for ABO-RH-K phenotyping and antibody detection. The magnetization of red cells avoids centrifugation and washing phases. This report describes the results of an evaluation of this new technology on its specific automated system. STUDY DESIGN AND METHODS ABO-RH-K phenotyping was compared between EMT and a semiautomated routine method (liquid microplate for ABO-D and microcolumn system for RH-K) on 311 patients' samples. The overall performance of the new method was further assessed in daily routine on a total of 11,022 samples during 3 months in two different laboratories. Antibody detection was evaluated on 624 consecutive patients' samples and on 118 frozen samples containing specific antibodies in comparison with commercial microcolumn systems. RESULTS Eight of 311 ABO-RH-K tests (2.6%) were not interpreted by EMT. Seven of them were weak antigen or reverse grouping reactions showing a negative result with the routine method. On a 3-month follow-up, 216 of 11,022 tests (1.96%) were not interpreted by the system, 75 percent of them being due to weak or mixed-field reactions. EMT was better in detecting ABO-D mixed-field reaction than routine microplate method. Detection of clinically significant antibodies was similar between EMT and microcolumn. In contrast, EMT detected a markedly lower rate of presumed nonsignificant antibodies. The system presents an overall high reliability. CONCLUSION EMT is tailored to meet the needs of the transfusion service and represents an important advance in the field of immunohematology.
منابع مشابه
EFFECT OF CHRONIC LEAD POISONING ON ERYTHROCYTE PROTOPORPHYRIN IN RATS
Research has shown that exposure to lead may have adverse effects at different blood lead concentrations. Lead inhibits at least two enzymes that are essential for the formation of heme, and because of the interaction of lead with these enzymes, no iron is inserted into protoporphyrin. Therefore the concentration of protoporphyrin increases in erythrocytes. The concentration of lead was mea...
متن کاملHLA-B27 Association with Uveitis in an Asian Indian Population
Background: Uveitis refers to diseases characterized by intraocular inflammation of the uveal tract. Anterior uveitis is a common ocular disease characterized by inflammation of the iris and the ciliary body. Objectives: To establish the frequency of HLA-B27- positive uveitis in Asian Indian population, study their clinical profile and compare it with other reports in literature. Methods: We re...
متن کاملAn Experimental Investigation of Magnetized Water Effect on Formation Damage
In oil industries, water injection into oil reservoirs for pressure maintenance, oil displacement, and oil recovery is a common technique. Formation damage during water injection is a major problem in this process. Formation damage from the incompatibility of formation water (FW) and injection water (IW) causes a reduction in the permeability around the injection wells. Therefore, it is necessa...
متن کاملStudies of Human HbAA Erythrocyte Osmotic Fragility Index of Non-Malarious Blood in the Presence of Five Anti-malarial Drugs
Background: The capacity of human HbAA erythrocytes of non-malarious blood to withstand osmotic stress in the presence of five antimalarial drugs, Chloroquine phosphate, Quinine, FansidarTM, CoartemTM and HalfanTM was studied in vitro. Materials and Methods: Aqueous solutions of four increasing concentrations of the drugs used in this investigation were in the order: 0.2%, 0.4%, 0.6% and 0.8% (...
متن کاملEffects of intense laser pulse properties on wake field acceleration in magnetized plasma: Half-Sine Shape (HSS) and Gaussian Shape (GS) pulses
In this paper, we have simulated the excitation of wake fields in the interaction of an intensive laser pulses having Half-Sine and Gaussian time envelopes with a fully ionized cold plasma using particle in cell (PIC) method. We investigated the dependency of wake filed amplitude to different laser and plasma parameters such as laser wavelength, pulse duration and electron number density. In ad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transfusion
دوره 48 9 شماره
صفحات -
تاریخ انتشار 2008