Agreement between total corneal astigmatism calculated by vector summation and total corneal astigmatism measured by ray tracing using Galilei double Scheimpflug analyzer.

نویسندگان

  • Sepehr Feizi
  • Siamak Delfazayebaher
  • Vahid Ownagh
  • Fatemeh Sadeghpour
چکیده

PURPOSE To evaluate the agreement between total corneal astigmatism calculated by vector summation of anterior and posterior corneal astigmatism (TCAVec) and total corneal astigmatism measured by ray tracing (TCARay). METHODS This study enrolled a total of 204 right eyes of 204 normal subjects. The eyes were measured using a Galilei double Scheimpflug analyzer. The measured parameters included simulated keratometric astigmatism using the keratometric index, anterior corneal astigmatism using the corneal refractive index, posterior corneal astigmatism, and TCARay. TCAVec was derived by vector summation of the astigmatism on the anterior and posterior corneal surfaces. The magnitudes and axes of TCAVec and TCARay were compared. The Pearson correlation coefficient and Bland-Altman plots were used to assess the relationship and agreement between TCAVec and TCARay, respectively. RESULTS The mean TCAVec and TCARay magnitudes were 0.76±0.57D and 1.00±0.78D, respectively (P<0.001). The mean axis orientations were 85.12±30.26° and 89.67±36.76°, respectively (P=0.02). Strong correlations were found between the TCAVec and TCARay magnitudes (r=0.96, P<0.001). Moderate associations were observed between the TCAVec and TCARay axes (r=0.75, P<0.001). Bland-Altman plots produced the 95% limits of agreement for the TCAVec and TCARay magnitudes from -0.33 to 0.82D. The 95% limits of agreement between the TCAVec and TCARay axes was -43.0 to 52.1°. CONCLUSION The magnitudes and axes of astigmatisms measured by the vector summation and ray tracing methods cannot be used interchangeably. There was a systematic error between the TCAVec and TCARay magnitudes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism.

PURPOSE Description of total corneal refractive power (TCRP) astigmatism by ray tracing using a Scheimpflug tomographer. METHODS Analysis of Scheimpflug tomography measurements to determine 3-mm-zone TCRP astigmatism (CATCRP) by ray tracing calculations, astigmatism in 15°-zone from simulated keratometry (CASim-K), anterior-surface astigmatism (CAant), and posterior-surface astigmatism (CApos...

متن کامل

Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism.

PURPOSE To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Case series. METHODS Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postop...

متن کامل

Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer

OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...

متن کامل

Contribution of posterior corneal astigmatism to total corneal astigmatism.

PURPOSE To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer. SETTING Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN Case series. METHODS Total corneal astigmatism was calculated using ray trac...

متن کامل

The Effect of Corneal Irregularity on Astigmatism Measurement by Automated versus Ray Tracing Keratometry

The aim of this study was to compare the effect of corneal irregularity on astigmatism assessment using automated keratometry (AK) (IOLMaster) versus ray tracing keratometry (Pentacam). This is an observational case series approved by the institutional review board of Dongguk University Hospital, Goyang, South Korea. A total of 207 eyes of 207 cataract patients were included. Preoperative corne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of optometry

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2018