Measurements of the dielectric (or impedance) properties of cells can be used as a general characterization and diagnostic tool. In this paper, we describe a novel impedance spectroscopy technique for the analysis of single biological cells in suspension. The technique uses maximum length sequences (MLS) for periodic excitation signal in a microfluidic impedance cytometer. The method allows multi-frequency single cell impedance measurements to be made in a short time period (ms). Spectral information is obtained in the frequency domain by applying a fast M-sequence transform (FMT) and fast Fourier transform (FFT) to the time domain response. Theoretically, the impedance is determined from the transfer function of the system when the MLS is a current excitation. The order of the MLS and sampling rate of A/D conversion are two factors that determine the bandwidth and spectral accuracy of the technique. Experimentally, the applicability of the technique is demonstrated by characterizing the impedance spectrum of red blood cells (RBCs) in a microfluidic cytometer. The impedance is measured within 1 ms at 512 discrete frequencies, evenly distributed in the range from 976.56 Hz to 500 kHz. The measured spectrum shows good agreement with simulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impedance spectroscopy using maximum length sequences: application to single cell analysis.

A maximum length sequence (MLS) is used to perform broadband impedance spectroscopy on a dielectric sample. The method has a number of advantages over other pulse-based or frequency sweep techniques. It requires the application of a very short sequence of voltage steps in the microsecond range and therefore allows the measurement of time-dependent impedance of a sample with high temporal resolu...

متن کامل

High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences.

A novel impedance spectroscopy technique has been developed for high speed single biological particle analysis. A microfluidic cytometer is used to measure the impedance of single micrometre sized latex particles at high speed across a range of frequencies. The setup uses a technique based on maximum length sequence (MLS) analysis, where the time-dependent response of the system is measured in ...

متن کامل

Study the Effect of Silicon Nanowire Length on Characteristics of Silicon Nanowire Based Solar Cells by Using Impedance Spectroscopy

Silicon nanowire (SiNW) arrays were produced by electroless method on polycrystalline Si substrate, in HF/ AgNO3 solution. Although the monocrystalline silicon wafer is commonly utilized as a perfect substrate, polycrystalline silicon as a low cost substrate was used in this work for photovoltaic applications. In order to study the influence of etching time (which affects the SiNWs length) on d...

متن کامل

Electrochemical Impedance Spectroscopy for Investigation of Different Losses in 4-cells Short Stack with Integrated Humidifier and Water Separator

Electrochemical impedance spectroscopy (EIS) is a suitable and powerful diagnostic testing method for fuel cells (FCs) since it is non-destructive and provides useful information about FC performance and its components. In this study, for the first time, a 500W cascade type 4 cells stack with integrated humidifier, water separator and internal manifolds was designed, fabricated and tested. The ...

متن کامل

Adaptive signal sampling for high throughput, broadband impedance spectroscopy

High throughput applications using broadband impedance spectroscopy as method for label free detection are limited by measurement speed and the enormous amount of raw data. Although often ignored, the fastest method for determining the passive electrical properties is the processing of the answer after step excitation. Sampling with constant time interval is common but not feasible for real tim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007