Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.

نویسندگان

  • Clarissa Teles Rodrigues
  • Marco Antonio Hungaro Duarte
  • Marcela Milanezi de Almeida
  • Flaviana Bombarda de Andrade
  • Norberti Bernardineli
چکیده

INTRODUCTION The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. METHODS Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesign R 25/.06 followed by ProDesign Logic 40/.05 and ProDesign Logic 50/.01 files; and Gates-Glidden drills, Hedström files, and K-files up to apical size 30 followed by K-file 40 and K-file 50 up to the working length. Micro-computed tomography scans were performed before and after each reinstrumentation procedure to evaluate root canal filling removal. Statistical analysis was performed with Kruskal-Wallis, Friedman, and Wilcoxon tests (P < .05). RESULTS No significant differences in filling material removal were found in the 3 groups of teeth. The use of Mtwo and ProDesign Logic 40/.05 rotary files did not enhance filling material removal after the use of reciprocating files. The use of ProDesign Logic 50/.01 files significantly reduced the amount of filling material at the apical levels compared with the use of reciprocating files. CONCLUSIONS Association of reciprocating and rotary files was capable of removing a large amount of filling material in the retreatment of curved canals, irrespective of the type of alloy of the instruments. The use of a ProDesign Logic 50/.01 file for apical preparation significantly reduced the amount of remnant material in the apical portion when compared with reciprocating instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments

Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandib...

متن کامل

Efficacy of Reciproc® and Profile® Instruments in the Removal of Gutta-Percha from Straight and Curved Root Canals ex Vivo

OBJECTIVES To compare the efficacy of Reciproc(®) (VDW GmbH) and ProFile(®) (Dentsply Maillefer) instruments at removing gutta-percha from straight and curved root canals ex vivo filled using the cold lateral condensation and GuttaMaster(®) (VDW GmbH) techniques. MATERIAL AND METHODS Forty mesial roots of mandibular molars with two curved canals and 80 single-rooted teeth with straight root c...

متن کامل

3D Analysis of D-RaCe and Self-Adjusting File in Removing Filling Materials from Curved Root Canals Instrumented and Filled with Different Techniques

The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF) system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT). The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual) were instrumented with SAF or Re...

متن کامل

ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy.

AIM To investigate physical parameters for ProTaper nickel-titanium (NiTi) rotary instruments whilst preparing curved canals in maxillary molars in vitro. METHODOLOGY A novel torque-testing platform was used to prepare root canals in 15 extracted human maxillary molars with ProTaper rotary instruments. Peak torque and force was registered along with numbers of rotations required to shape the ...

متن کامل

Efficacy Of Various Instrumentation Techniques For Removing Filling Material During Root Canal Retreatment Using Cone Bean Computed Tomography –An In-Vitro Study

Aim: To compare the efficacy of various instrumentation techniques for removing obturating material from root canals using Cone Bean Computed Tomography (CBCT). Materials and Methods: Thirty extracted human premolar teeth, each with a single canal were selected. The root canals were prepared upto F4 ProTaper file and obturated with corresponding gutta percha cone. Teeth were divided into three ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 42 11  شماره 

صفحات  -

تاریخ انتشار 2016