Metal Artifact Reduction in Dental Computed Tomography Images Based on Sinogram Segmentation Using Curvelet Transform Followed by Hough Transform
نویسندگان
چکیده
In X-ray computed tomography (CT), the presence of metal objects in a patient's body produces streak artifacts in the reconstructed images. During the past decades, many different methods were proposed for the reduction or elimination of the streaking artifacts. When scanning a patient, the projection data affected by metal objects (missing projections) appear as regions with high intensities in the sinogram. In spiral fan beam CT, these regions are sinusoid-like curves on sinogram. During the first time, if the metal curves are detected carefully, then, they can be replaced by corresponding unaffected projections using other slices or opposite views; therefore, the CT slices regenerated by the modified sonogram will be imaged with high quality. In this paper, a new method of the segmentation of metal traces in spiral fan-beam CT sinogram is proposed. This method is based on a sinogram curve detection using a curvelet transform followed by 2D Hough transform. The initial enhancement of the sinogram using modified curvelet transform coefficients is performed by suppressing all the coefficients of one band and applying 2D Hough transform to detect more precisely metal curves. To evaluate the performance of the proposed method for the detection of metal curves in a sinogram, precision and recall metrics are calculated. Compared with other methods, the results show that the proposed method is capable of detecting metal curves, with better precision and good recovery.
منابع مشابه
Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
متن کاملA New Method for Metal Artifact Reduction in CT Scan Images
Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملNon-equispaced Fourier Transform Vs. Polynomial-Based Metal Artifact Reduction in Computed Tomography
We propose a method, which treats metal artifact reduction in CT by sinogram restoration as a problem of scattered data interpolation. Corrupted sinogram entries are discarded and replaced with artificially generated values. The presented interpolation algorithm is based on the 2D non-equispaced fast Fourier transform (NFFT). Results are compared to two common polynomial interpolation schemes.
متن کامل