A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer

نویسندگان

  • Sarah Hart
  • Kathryn Drevets
  • Micah Alford
  • Amanda Salacinski
  • Brian E Hunt
چکیده

OBJECTIVES The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability. DESIGN In this method comparison study we compared blood lactate concentration measured using the Lactate Plus portable analyzer to lactate concentration measured by a reference analyzer, the YSI 2300. SETTING University campus in the USA. PARTICIPANTS Fifteen active men and women performed a discontinuous graded exercise test to volitional exhaustion on a motorised treadmill. Blood samples were taken via finger prick and collected in microcapillary tubes for analysis by the reference instrument at the end of each stage. Duplicate samples for the portable analyzer were either taken directly from the finger or from the micro capillary tubes. PRIMARY OUTCOME MEASUREMENTS: Ordinary least products regressions were used to assess validity, reliability and bias in the portable analyzer. Lactate threshold was determined by visual inspection. RESULTS Though measurements from both instruments were correlated (r=0.91), the differences between instruments had large variability (SD=1.45 mM/l) when blood was sampled directly from finger. This variability was reduced by ∼95% when both instruments measured blood collected in the capillary tubes. As the proportional and fixed bias between instruments was small, there was no difference in estimates of the lactate threshold between instruments. Reliability for the portable instrument was strong (r=0.99, p<0.05) with no proportional bias (slope=1.02) and small fixed bias (-0.19 mM/l). CONCLUSIONS The Lactate Plus analyzer provides accurate and reproducible measurements of blood lactate concentration that can be used to estimate workloads corresponding to blood lactate transitions or any absolute lactate concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Value of Cast Analyzer X Iranian Software versus Curve Expert Software for Arch Form Construction based on Mathematical Models

  Objective: For the assessment of primary arch form, different methods have been used including qualitative classifications, inter-canine and inter-molar widths and quantitative and numerical methods using mathematical models. The purpose of this study was to compare the validity and reliability of Cast Analyzer X Iranian software with those of Curve Expert Professional version 1.1 for arch fo...

متن کامل

Reliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle

Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...

متن کامل

Combat Readiness Test: Design and Validation in the Iranian Military

Background and Aim: Physical fitness is a major contributor to combat readiness, and current military tests do not measure it appropriately. The purpose of this study was to design a combat readiness test that could reliably and consistently determine the level of physical fitness distinctly required prior to deployment into the battlefield. Methods: The subjects of this study were military per...

متن کامل

فرایند ارزیابی روایی و پایایی ابزار‌های سنجش و اندازه‌گیری در تحقیقات آموزشی، رفتاری و علوم سلامت ( با تأکید بر روایی محتوا)

Development and assessment of measurement tools are important stages in the research processes regarding social, educational, and medical sciences, which mainly focus on the measurement of characteristics, qualitative variables, and abstract variables. Validity and reliability are two important components of researcher-made tools. The quality of assessment and confirming of validity and reliabi...

متن کامل

Design a questionnaire to survey Knowledge, Attitude and Practice (KAP) of printing industry workers Regarding to Hearing Protection and determining its validity and reliability

Introduction: In many countries, the noise has been ranked among the important risk factors in the printing industries. The purpose of this study is to design a tool for Assessing the level of knowledge, attitude and practice of the printing industry workers in the field of hearing protection and determining its validity and reliability. Methods: To design a questionnaire, 35 questions were pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013