Pulse Wave Reflection: Can It Explain the Differences Between Systemic and Pulmonary Pressure and Flow Waves? A Study in Dogs

نویسنده

  • G. C. van den Bos
چکیده

We have studied the effect of changes in pulse wave reflection on the configurations of pressure and flow in systemic and pulmonary circulation. Electromagnetic flow transducers, atrial catheters, and pacing leads were implanted in 10 dogs. In four animals, the flow transducer was placed on the pulmonary artery, in another four on the ascending aorta, and in two additional dogs on both vessels. One week later, ascending aortic and/or pulmonary artery flow and pressure (catheter tip manometer) were measured under general anesthesia (Nembutal, 30 mg/kg, iv). When the pulmonary circulation was studied (six dogs), measurements were made before and during serotonin infusion (0.5-0.75 mg/min). When the systemic circulation was studied (six dogs), measurements were made before and during nitroprusside infusion (50-200 jug/min). To quantify the arterial load, we calculated pulmonary and systemic input impedances. To estimate the amount of reflection, we used a reflection index which we defined as the amplitude ratio of reflected and forward wave. Nitroprusside decreased total peripheral resistance, increased total arterial compliance, and decreased the reflection index; similarity between aortic pressure and flow wave shapes increased, and they looked more like their pulmonary counterparts. Serotonin increased pulmonary vascular resistance, decreased pulmonary arterial compliance, and increased the reflection index. Resemblance of pressure and flow waves decreased. The differences in wave shapes can thus be explained by the amount of reflection: the less reflection the more pressure and flow resemble each other. (Circ Res 51: 479-485, 1982)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse wave reflection: can it explain the differences between systemic and pulmonary pressure and flow waves? A study in dogs.

We have studied the effect of changes in pulse wave reflection on the configurations of pressure and flow in systemic and pulmonary circulation. Electromagnetic flow transducers, atrial catheters, and pacing leads were implanted in 10 dogs. In four animals, the flow transducer was placed on the pulmonary artery, in another four on the ascending aorta, and in two additional dogs on both vessels....

متن کامل

Reflections on wave reflections in chronic thromboembolic pulmonary hypertension.

Chronic thromboembolic pulmonary hypertension (CTEPH) is a surgically curable form of severe pulmonary hypertension. However, in 10% of the patients, the procedure may not be successful, because of persistent pulmonary hypertension after removal of proximally located thromboembolic material. This complication is of particularly poor prognosis. In the present issue of the European Heart Journal,...

متن کامل

Impact of Initial Stress on Reflection and Transmission of SV-Wave between Two Orthotropic Thermoelastic Half-Spaces

Reflection and transmission of plane waves between two initially stressed thermoelastic half-spaces with orthotropic type of anisotropy is studied. Incidence of a SV-type wave from the lower half-space is considered and the amplitude ratios of the reflected and transmitted SV-wave, P-wave and thermal wave are obtained by using appropriate boundary conditions. Numerical computation for a particu...

متن کامل

Ultrasonic guided waves reflection from simple dent in pipe for defect rate estimation and parameters determination of axisymmetric wave generation source

In this paper, the reflection of ultrasonic guided waves from simple dent in pipes has been investigated using finite element method and the relationship between reflection coefficient of these waves and deformation rate has been determined. Also, the effect of the parameters of wave generation source on the generated wave field has been investigated using normal modes expansion method. At firs...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005