OBJECTIVE Overnight polysomnography (PSG) is the gold standard diagnostic tool for sleep apnea-hypopnea syndrome (SAHS) in children. The aim of the present study was to evaluate the usefulness of diagnostic respiratory polygraphy in children with clinically suspected SAHS referred to our sleep-disordered breathing clinic. PATIENTS AND METHODS We studied 53 children referred with clinical suspicion of SAHS; 29 (54.7%) were boys and the mean (SD) age was 6.4 (2.9) years. After a medical history was taken and a physical examination performed, patients underwent respiratory polygraphy (Edentec) simultaneously with overnight PSG in the sleep laboratory. The 2 diagnostic tools were compared using statistical analysis. RESULTS SAHS was defined by an obstructive apnea-hypopnea index (OAHI) of 3 or more in overnight PSG and a respiratory disturbance index (RDI) of 3 or more in respiratory polygraphy. The rate of diagnostic agreement was 84.9%. The difference between the mean OAHI and RDI values was not significant (0.7 +/- 5.4; P=.34). The intraclass correlation coefficient between the OAHI and RDI was 89.4 (95% confidence interval, 82.4-93.7; P< .001). When receiver operating characteristic curves were calculated for the OAHI cutoff points used for the diagnosis of SAHS (> or =1, > or =3, and > or =5), the best RDI cutoff for all 3 OAHI values considered was found to be 4.6. When age strata were considered, in children 6 years or older the best RDI cutoff for the 3 OAHI values was 2.1. In children younger than 6 years the best RDI cutoff was 3.35 for OAHI > or =1 and 5.85 for OAHI > or =3 and > or =5. CONCLUSIONS Respiratory polygraphy in the sleep laboratory is a valid method for the diagnosis of SAHS in children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Reliability of home respiratory polygraphy for the diagnosis of sleep apnea-hypopnea syndrome: analysis of costs].

OBJECTIVES To evaluate the reliability of home respiratory polygraphy for the diagnosis of sleep apnea-hypopnea syndrome (SAHS) and to compare the cost of this technique with that of nighttime polysomnography performed in a sleep laboratory. PATIENTS AND METHODS This was a prospective study of a random sample of patients with clinically suspected SAHS in which the participants who underwent b...

متن کامل

[Validation of a respiratory polygraphy system in the diagnosis of sleep apnea syndrome].

OBJECTIVE To validate a cardiorespiratory polygraphy system (BITMED NGP 140) by comparing it to conventional polysomnography in the diagnosis of sleep apnea-hypopnea syndrome. PATIENTS AND METHODS Polysomnography and cardio-respiratory polygraphy were performed simultaneously on 103 consecutive patients referred because of suspected sleep apnea-hypopnea syndrome. The Bland and Altman method a...

متن کامل

Determination of The Relationship Between Severity of Obstructive Sleep Apnea And Chronic Obstructive Pulmonary Disease

Introduction: Chronic obstructive pulmonary disease (COPD) patients are at increased risk of sleep-disorders. The concomitant occurrence of COPD and obstructive sleep apnea hypopnea syndrome (OSAHS) is named overlap syndrome. This study aimed to evaluate the severity of OSAHS in overlap syndrome patients.Materials & Methods: This cross-sectional study was conducted on adult patients with forced...

متن کامل

The Evaluation of Diastolic Hypertention in Sleep Overlap Syndrome

Introduction:The overlap syndrome, consisting ofobstructive sleep apnea hypopnea syndrome (OSAHS) and chronic obstructvie pulmonary disease (COPD) is a major problem in COPD patients. OSHAS corresponds to the likelihood of systemic hypertension.The present study was aimed to evaluate the association between apnea-hypopnea index and diastolic blood presssure (DBP) in overlap  patients. Materials...

متن کامل

[Obstructive sleep apnea-hypopnea syndrome in children is not associated with obesity].

OBJECTIVE The prevalence of obstructive sleep apnea-hypopnea syndrome (OSAHS) in the general pediatric population ranges from 1% to 3%. However, its prevalence in an unselected population of obese children is unknown. We studied the association between obesity and OSAHS in children diagnosed with the syndrome in a cohort of boys and girls (age range, 2-14 years) referred to the pediatric respir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de bronconeumologia

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2008