The illumination characteristics of operative microscopes.

نویسندگان

  • Christopher A Schutt
  • Brandon Redding
  • Hui Cao
  • Elias Michaelides
چکیده

PURPOSE Modern operative microscopes use light sources which possess the power to severely damage underlying tissue. Currently, manufacturers provide a safety warning of this possibility. However, they are unable to suggest specific settings due to a stated "lack of scientific publications on this topic". We aim to radiometrically evaluate multiple otologic microscopes at variables which effect irradiance in order to determine reference emissions levels and provide guidelines for improved intraoperative safety. MATERIALS AND METHODS The optical radiance of four otologic microscopes was evaluated at variable field illumination sizes (spot size), intensity settings and working distances. The spectral emission of each microscope was separately measured. The energy absorbed in skin with representative properties was then calculated as a function of time for each microscope by accounting for the emission spectrum of the microscope and the absorption spectrum of skin. RESULTS Microscopes showed a wide range of optical radiance based on model, spots size, intensity setting and working distances. Spectral emission of all four microscopes was centered in the visible spectrum with minimal ultraviolet or infrared contribution. A large amount of energy is absorbed by skin during usage of operative microscopes. The highest calculated absorption at 200 min of use was 736.26 J/cm(2). CONCLUSIONS Operative microscopes have the ability to cause patient morbidity secondary to the energy they impart. In an effort to decrease potential injury we recommend that physicians be aware of their microscopes properties and how to control variables which effect irradiance of the skin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Red Reflex and Surgeon Preference Between Nearly-Collimated and Focused Beam Microscope Illumination Systems.

PURPOSE To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. METHODS This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey complete...

متن کامل

Quantitative evaluation and comparison of light microscopes

We have developed and applied a procedure based on digital image processing to evaluate the performance of automated and semi-automated light microscopes. We evaluate the homogeneity of illumination to see if there is significant shading. We can measure the characteristics of the stage motion in the x, y, and z directions as to accuracy, precision, and hysteresis effects. We determine the OTF o...

متن کامل

تحلیل تطبیقی آرایه های تذهیب صفحات افتتاحیۀ در نُسَخ مکاتب شیراز آل اینجو و تیموری

The present study seeks for to examining the components of illumination of the Frontispieces in Injuid and Timurid Shiraz School. The aim of the study is to explain the main reasons in change of approach and dominant styles in illuminated manuscripts throughout a century within the identical origins. In addition, the present study compares the structural and formal characteristics of illuminate...

متن کامل

Skylight Design Regulation for Residential Building in Hamadan City

Skylights or light wells are an integral part of the design of low- and high-depth buildings. The design of these skylights in different areas is based on specific criteria. According to Hamedan's criteria, only the dimensions of these skylights and the ratio of skylight area to height of the skylight are enough to design skylights. The purpose of this study was to evaluate the accuracy of sk...

متن کامل

تطبیق تذهیب‌های سه نسخه از قرآن‌های دوره قاجار با تأکید بر ویژگی‌های بصری آنها

The Quran’s illumination forms are important parts of the Iranian illumination art. This research considers the recognition of the visual features of Quranic illumination in Qajar period. The motif, color and combination of the important factors of Quranic illumination are used to classify the illumination. These factors have been selected of the Qajar period in three versions of the illu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of otolaryngology

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2015