Deceleration time of systolic pulmonary venous flow: a new clinical marker of left atrial pressure and compliance.
نویسندگان
چکیده
The curvilinearity of the atrial pressure-volume curve implies that atrial compliance decreases progressively with increasing left atrial (LA) pressure (LAP). We predicted that reduced LA compliance leads to more rapid deceleration of systolic pulmonary venous (PV) flow. With this rationale, we investigated whether the deceleration time (t dec) of PV systolic flow velocity reflects mean LAP. In eight patients during coronary surgery, before extracorporeal circulation, PV flow by ultrasonic transit time and invasive LAP were recorded during stepwise volume loading. The t dec was calculated using two methods: by drawing a tangent through peak deceleration and by drawing a line from peak systolic flow through the nadir between the systolic and early diastolic flow waves. LA compliance was calculated as the systolic PV flow integral divided by LAP increment. Volume loading increased mean LAP from 11 +/- 3 to 20 +/- 5 mmHg (P < 0.001) (n = 40), reduced LA compliance from 1.16 +/- 0.42 to 0.72 +/- 0.40 ml/mmHg (P < 0.004) (n = 40), and reduced t dec from 320 +/- 50 to 170 +/- 40 ms (P < 0.0005) (n = 40). Mean LAP correlated well with t dec (r = 0.84, P < 0.0005) (n = 40) and LA compliance (r = 0.79, P < 0.0005) (n = 40). Elevated LAP caused a decrease in LA compliance and therefore more rapid deceleration of systolic PV flow. The t dec has potential to become a semiquantitative marker of LAP and an index of LA passive elastic properties.
منابع مشابه
Pulmonary venous flow assessed by Doppler echocardiography in the management of atrial fibrillation.
Pulmonary venous blood flow (PVF) visualized by Doppler echocardiography exhibits a pulsatile behavior, which is related to left atrial pressure and function, mitral valve function, and left ventricular compliance. In atrial fibrillation (AF), the disappearance of atrial reverse flow, a decrease in systolic flow with a greater diastolic than systolic flow, a prolonged onset of systolic flow and...
متن کاملDoppler evaluation of severity of mitral regurgitation: relation to pulmonary venous blood flow patterns in an animal study.
OBJECTIVES This study examined the influence of regurgitant volume on pulmonary venous blood flow patterns in an animal model with quantifiable mitral regurgitation. BACKGROUND Systolic pulmonary venous blood flow is influenced by atrial filling and compliance and ventricular output and by the presence of mitral regurgitation. The quantitative severity of the regurgitant volume itself is diff...
متن کاملCor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report
Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium through restrictive opening to the low-pressure, dis...
متن کاملAbnormalities of pulmonary venous flow in patients with lone atrial fibrillation.
AIMS Mechanisms underlying lone atrial fibrillation (LAF) are poorly defined. We sought to investigate indices of left atrial (LA) function in patients with recurrent LAF, in comparison with that in healthy subjects. METHODS AND RESULTS Investigations were performed in 42 patients aged 51.8 +/- 8.7 at least 30 days after the last episode of LAF and in 38 healthy controls. Each subject underwe...
متن کاملEstimation of mean left atrial pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow.
To determine whether pulmonary venous flow and mitral inflow measured by transesophageal pulsed Doppler echocardiography can be used to estimate mean left atrial pressure (LAP), we prospectively studied 47 consecutive patients undergoing cardiovascular surgery. We correlated Doppler variables of pulmonary venous flow and mitral inflow with simultaneously obtained mean LAP and changes in pressur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 100 2 شماره
صفحات -
تاریخ انتشار 2006