Repeatability of aberrometric measurements in normal and keratoconus eyes using a new Scheimpflug-Placido topographer.
نویسندگان
چکیده
PURPOSE To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes. SETTING Bozok University Faculty of Medicine, Yozgat, Turkey. DESIGN Evaluation of diagnostic test. METHODS In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained using the Scheimpflug-Placido topographer. Repeatability of the corneal aberrometric data using a 7th-order Zernike expansion (6.0 mm pupil) and central corneal power (3.0 mm zone) in the anterior and posterior corneal surfaces were analyzed. The within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC) were calculated. RESULTS For all modal pairs, the Sw was 0.08 μm or less for anterior and posterior corneal aberrations in both groups. The ICC of the anterior corneal surface ranged from 0.607 (pentafoil) to 0.988 (primary coma) in keratoconus eyes (n = 41) and from 0.568 (quadrifoil) to 0.856 (primary coma) in normal eyes (n = 30). The ICCs for posterior corneal surface aberrometry were 0.656 to 0.873 and 0.592 to 0.824, respectively. For anterior and posterior corneal curvatures, the Sw was 0.12 or lower and the ICC values were more than 0.93 in all cases except the posterior corneal surface reading at the 3.0 mm corneal area in keratoconus eyes (ICC 0.875). CONCLUSIONS The intraexaminer repeatability of most anterior corneal aberrations with the Scheimpflug-Placido system was moderate to high in normal eyes and keratoconus eyes. The system showed moderate repeatability for the posterior corneal surface. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
BACKGROUND/AIMS This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology. CASE DESCRIPTION A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between hi...
متن کاملSingle session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device
PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...
متن کاملRepeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...
متن کاملAssessment of anterior segment parameters in morbid obesity
Abstract. – OBJECTIVE: To investigate the measurement of anterior segment parameters using Sirius Scheimpflug-Placido topographer, Lenstar optical low coherence reflectometry (OLCR), and noncontact specular microscopy (SM) in morbidly obese and nonobese subjects. PATIENTS AND METHODS: Twenty-eight morbidly obese subjects (BMI ≥ 40; Group 1) and 28 agesex-matched healthy nonobese subjects (BMI 1...
متن کاملOCT corneal epithelial topographic asymmetry as a sensitive diagnostic tool for early and advancing keratoconus
PURPOSE To investigate epithelial thickness-distribution characteristics in a large group of keratoconic patients and their correlation to normal eyes employing anterior-segment optical coherence tomography (AS-OCT). MATERIALS AND METHODS The study group (n=160 eyes) consisted of clinically diagnosed keratoconus eyes; the control group (n=160) consisted of nonkeratoconic eyes. Three separate,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2014