Echo time dependence of laminar BOLD activation at 7 Tesla

نویسندگان

  • P. J. Koopmans
  • M. Barth
  • D. G. Norris
چکیده

Introduction We present a multi-echo fMRI study at 7 T with 0.75 mm isotropic voxels and TEs ranging from 4.8 to 56 ms. This makes it possible to determine T2 at an unprecedented spatial scale making it possible to assess the local influence of myelinisation and vascularisation. As expected [1], the signal superficial to the cortex decays non-mono-exponentially because of a mixed compartment of venous blood (short T2/T2, complex decay pattern) and CSF (long T2/T2). Simultaneously the echo-time dependence of the functional activation in different layers is investigated, where the expectation is that activation in the pial veins will peak at an earlier TE than within GM due to the short T2 of blood at high field strengths [2,3]. It is not to be expected however that after this initial peak the activation will completely disappear because the pial veins are surrounded by CSF and hence there will be a significant extravascular contribution at later TEs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distinguishing pial and laminar gradient-echo BOLD signals at 7 Tesla

Introduction With high field scanners and multi-channel coil arrays becoming more readily available, high resolution fMRI methods may be capable of detecting neural responses at the laminar level. First results in animals indicate that gradient-echo (GE) is not able to depict laminar activation [1-4] and this has been attributed to the large BOLD contribution of the pial veins corrupting the la...

متن کامل

Fat Suppression with Low SAR for SE EPI fMRI at 7T

Introduction: Functional imaging studies at 7 Tesla have given encouraging results, with increased CNR and stronger BOLD contrast [1]. However, a remaining problem at such field strengths is the increased specific absorption rate (SAR). A possible solution would be the omission or the modification of the RF pulses used in the imaging sequence. The SAR for gradient-echo EPI at 7 Tesla can be red...

متن کامل

BOLD fMRI signal characteristics of S1- and S2-SSFP at 7 Tesla

OBJECT To compare the BOLD fMRI signal characteristics at in the cortex and on the pial surface for a non-balanced steady-state free precession sequence (nb-SSFP) at 7 T. MATERIALS AND METHODS A multi-echo nb-SSFP sequence was used for high resolution fMRI at 7 T. Two S1 (S(+)) echoes at different echo times were acquired together with an S2 (S(-)) echo. The primary visual cortex (V1) was exa...

متن کامل

Comparison of the dependence of blood R2 and R2* on oxygen saturation at 1.5 and 4.7 Tesla.

Gradient-echo (GRE) blood oxygen level-dependent (BOLD) effects have both intra- and extravascular contributions. To better understand the intravascular contribution in quantitative terms, the spin-echo (SE) and GRE transverse relaxation rates, R(2) and R(2)(*), of isolated blood were measured as a function of oxygenation in a perfusion system. Over the normal oxygenation saturation range of bl...

متن کامل

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.

The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non-invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009