Automatic detection of left ventricular ejection time from a finger photoplethysmographic pulse oximetry waveform: comparison with Doppler aortic measurement.
نویسندگان
چکیده
Left ventricular ejection time (LVET) is a useful measure of ventricular performance and preload. The present study explores a novel method of continuous LVET monitoring using a noninvasive finger photoplethysmographic pulse oximetry waveform (PPG-POW). A method for the automatic beat-to-beat detection of LVET from the finger PPG-POW is presented based on a combination of derivative analysis, waveform averaging and rule-based logic. The performance of the detection method was evaluated on 13 healthy subjects during graded head-up tilt. Overall, the correlation between the PPG-POW derived LVET and the aortic flow derived LVET was high and significant (r = 0.897, p < 0.05). The bias was -14 +/- 14 ms (mean +/- SD), and the percentage error was 9.7%. Although these results would not be sufficient to satisfy the requirement for clinical evaluation of LVET when absolute accuracy was demanded, the strong correlation between the PPG-POW LVET and the aortic LVET on an intra-subject basis (r = 0.945 +/- 0.043, mean +/- SD) would support the application of PPG-POW to detect the directional change in LVET of an individual. This could be very useful for the early identification of progressive hypovolaemia or blood loss. The present study has demonstrated a promising approach to extract potentially useful information from a noninvasive, easy-to-obtain signal that could be readily acquired either from existing patient monitoring equipment or from inexpensive instrumentation. More extensive investigation is necessary to evaluate the applicability of the present approach in clinical care monitoring.
منابع مشابه
Detecting change in left ventricular ejection time during head-up tilt-induced progressive central hypovolemia using a finger photoplethysmographic pulse oximetry wave form.
BACKGROUND Change in cardiac preload caused by mild hypovolemia can alter left ventricular ejection time (LVET) without noticeable change in blood pressure (BP). Previously our group has explored a novel method of LVET monitoring using a noninvasive finger photoplethysmographic pulse oximetry wave form. The current study investigated the ability of photoplethysmographic pulse oximetry wave form...
متن کاملChanges in left ventricular ejection time and pulse transit time derived from finger photoplethysmogram and electrocardiogram during moderate haemorrhage.
OBJECTIVES Early identification of haemorrhage is difficult when a bleeding site is not apparent. This study explored the potential use of the finger photoplethysmographic (PPG) waveform derived left ventricular ejection time (LVET(p)) and pulse transit time (PTT) for detecting blood loss, by using blood donation as a model of controlled mild to moderate haemorrhage. METHODS This was a prospe...
متن کاملDoppler-Derived Myocardial Performance Index in Healthy Children in Shiraz
Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملPulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.
PURPOSE OF REVIEW This article reviews the development of novel reflectance pulse oximetry sensors for the esophagus and bowel, and presents some of the techniques used to analyze the waveforms acquired with such devices. RECENT FINDINGS There has been much research in recent years to expand the utility of pulse oximetry beyond the simple measurement of arterial oxygen saturation from the fin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 28 4 شماره
صفحات -
تاریخ انتشار 2007