On the Calibration of Focused Plenoptic Cameras

نویسندگان

  • Ole Johannsen
  • Christian Heinze
  • Bastian Goldlücke
  • Christian Perwass
چکیده

Plenoptic cameras provide a robust way to capture 3D information with a single shot. This is accomplished by encoding the direction of the incoming rays with a microlens array (MLA) in front of the camera sensor. In the focused plenoptic camera, a MLA acts like multiple small cameras that capture the virtual scene on the focus plane of a main lens from slightly different angles, which enables algorithmic depth reconstruction. This virtual depth is measured on the camera side, and independent of the main lens used. The connection between actual lateral distances and virtual depth, however, does depend on the main lens parameters, and needs to be carefully calibrated. In this paper, we propose an approach to calibrate focused plenoptic cameras, which allows a metric analysis of a given scene. To achieve this, we minimize an energy model based upon the thin lens equation. The model allows to estimate intrinsic and extrinsic parameters and corrects for radial lateral as well as radial depth distortion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stepwise calibration of focused plenoptic cameras

Monocular plenoptic cameras are slightly modified, off-the-shelf cameras that have novel capabilities as they allow for truly passive, high-resolution range sensing through a single camera lens. Commercial plenoptic cameras, however, are presently delivering range data in non-metric units, which is a barrier to novel applications e.g. in the realm of robotics. In this work we revisit the calibr...

متن کامل

Calibration and Accuracy Analysis of a Focused Plenoptic Camera

In this article we introduce new methods for the calibration of depth images from focused plenoptic cameras and validate the results. We start with a brief description of the concept of a focused plenoptic camera and how from the recorded raw image a depth map can be estimated. For this camera, an analytical expression of the depth accuracy is derived for the first time. In the main part of the...

متن کامل

Metric Calibration of a Focused Plenoptic Camera Based on a 3d Calibration Target

In this paper we present a new calibration approach for focused plenoptic cameras. We derive a new mathematical projection model of a focused plenoptic camera which considers lateral as well as depth distortion. Therefore, we derive a new depth distortion model directly from the theory of depth estimation in a focused plenoptic camera. In total the model consists of five intrinsic parameters, t...

متن کامل

Unconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibration

The plenoptic camera can capture both angular and spatial information of the rays, enabling 3D reconstruction by single exposure. The geometry of the recovered scene structure is affected by the calibration of the plenoptic camera significantly. In this paper, we propose a novel unconstrained two-parallel-plane (TPP) model with 7 parameters to describe a 4D light field. By reconstructing scene ...

متن کامل

Calibration of Plenoptic 2.0 Cameras and use in 3DPTV Investigations

Plenoptic 1.0 cameras have already been investigated as a means for performing 3DPIV. Plenoptic 2.0 cameras have an enhanced in-plane resolution, but are limited to less dense particle fields by their depth-detection method, and are thus less appropriate for 3DPIV. A technique more suited to less dense particle fields is 3DPTV. Time-resolved 3DPTV will be possible due to the high frame rate ava...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013