Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials.
نویسندگان
چکیده
This study compared the surface detail reproduction and dimensional accuracy of stone models obtained from molds disinfected with 2% sodium hypochlorite, 2% chlorhexidine digluconate or 0.2% peracetic acid to models produced using molds which were not disinfected, with 3 alginate materials (Cavex ColorChange, Hydrogum 5 and Jeltrate Plus). The molds were prepared over matrix containing 20-, 50-, and 75-µm lines, performed under pressure with perforated metal tray. The molds were removed following gelation and either disinfected (using one of the solutions by spraying followed by storage in closed jars for 15 min) or not disinfected. The samples were divided into 12 groups (n=5). Molds were filled with dental gypsum Durone IV and 1 h after the start of the stone mixing the models were separated from the tray. Surface detail reproduction and dimensional accuracy were evaluated using optical microscopy on the 50-µm line with 25 mm in length, in accordance with the ISO 1563 standard. The dimensional accuracy results (%) were subjected to ANOVA. The 50 µm-line was completely reproduced by all alginate impression materials regardless of the disinfection procedure. There was no statistically significant difference in the mean values of dimensional accuracy in combinations between disinfectant procedure and alginate impression material (p=0.2130) or for independent factors. The disinfectant solutions and alginate materials used in this study are no factors of choice regarding the surface detail reproduction and dimensional accuracy of stone models.
منابع مشابه
تعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالبگیری
Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...
متن کاملHardness and Surface Detail Reproduction of Gypsum Casts Retrieved from Addition Silicone Impressions Disinfected for Different Time Points
Background and Aim: Bacterial colonization occurs following contamination of impression materials with blood and saliva. However, not all disinfecting agents are compatible with the impression materials and may cause changes in the resultant casts. The purpose of this study was to assess the impact of various immersion time of addi-tion silicon impressions in different disinfecting solutions on...
متن کاملComparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials
Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability. Materials and Methods: In this in-vitro experimental study, dimensional changes of two t...
متن کاملEffect of Three Disinfectants on Dimensional Changes of Different Impression Materials
Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...
متن کاملتعیین دقت ثبت ایمپلنت و جزئیات سطحی با استفاده از پلیاتر و پلیوینیل سایلوکسان با روش تری بسته
Background and Aims: Making accurate impressions of prepared teeth when they are adjacent to dental implants is of great importance. In these situations, disregarding the selection of appropriate impression material and technique, not only can affect accuracy of transferring of the 3-dimentional spatial status of implant, but also can jeopardize the accurate recording of tooth. In the present...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 23 4 شماره
صفحات -
تاریخ انتشار 2012