The lateral tibial tunnel: does it allow for adequate fixation in ACL surgery?
نویسندگان
چکیده
UNLABELLED The purpose of this cadaver study about the ACL graft was to compare a "Lateral Tibial Tunnel" (LTT) and a "classic, anteroMedial Tibial Tunnel" (MTT), as to fixation strength and mode of failure. Ten pairs of fresh frozen human proximal tibias were used. In one of both tibias a classic anteromedial tunnel was used, versus a lateral tibial tunnel in the contralateral knee. Autologous doubled semitendinosus and gracilis tendons were fixed in the tunnels. A maximum load to failure test was performed to determine the stiffness and the strength of the graft-tibia complex. CONCLUSION for none of the measurements was there any significant difference between both tunnels. The tibial fixation strength of a human autologous doubled hamstring graft in ACL surgery is similar, whether a lateral or an anteromedial tibial tunnel is used. This is the first study investigating fixation strength of an ACL graft in a lateral tibial tunnel.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملEffect of PEEK polymer on tunnel widening after hamstring ACL reconstruction.
The purpose of this study was to evaluate the effect of the AperFix device (Cayenne Medical, Inc, Scottsdale, Arizona), composed of polyetheretherketone (PEEK) polymer, on tunnel widening after hamstring anterior cruciate ligament (ACL) reconstruction as compared with 2 other fixation devices: the TransFix (Arthrex, Inc, Naples, Florida) and the EndoButton (Smith & Nephew Endoscopy, Mansfield, ...
متن کاملThe WasherLoc and Bone Dowel: A Rigid, Slippage-Resistant Tibial Fixation Device for a Soft Tissue Anterior Cruciate Ligament Graft
The WasherLoc is a tibial fixation device for soft tissue anterior cruciate ligament (ACL) reconstruction that combines superior fixation properties (945 N strength, 507 N/mm stiffness, and high resistance to slippage) with a simple surgical technique. The WasherLoc is a washer with 13 short spikes that penetrate the soft tissue ACL graft in multiple locations and 4 long peripheral spikes that ...
متن کاملThree-Dimensional Reconstruction Computed Tomography Evaluation of Tunnel Location during Single-Bundle Anterior Cruciate Ligament Reconstruction: A Comparison of Transtibial and 2-Incision Tibial Tunnel-Independent Techniques
BACKGROUND Anatomic tunnel positioning is important in anterior cruciate ligament (ACL) reconstructive surgery. Recent studies have suggested the limitations of a traditional transtibial technique to place the ACL graft within the anatomic tunnel position of the ACL on the femur. The purpose of this study is to determine if the 2-incision tibial tunnel-independent technique can place femoral tu...
متن کاملRadiographic findings in revision anterior cruciate ligament reconstructions from the Mars cohort.
The Multicenter ACL (anterior cruciate ligament) Revision Study (MARS) group was developed to investigate revision ACL reconstruction outcomes. An important part of this is obtaining and reviewing radiographic studies. The goal for this radiographic analysis is to establish radiographic findings for a large revision ACL cohort to allow comparison with future studies. The study was designed as a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 78 5 شماره
صفحات -
تاریخ انتشار 2012