Evaluation of a rapid screening test for microalbuminuria with a spot measurement of urine albumin-creatinine ratio.

نویسندگان

  • W Y Ng
  • K F Lui
  • A C Thai
چکیده

INTRODUCTION Microalbuminuria has been established as a marker of incipient diabetic nephropathy, and a regular screening programme has been advocated in patients with diabetes mellitus. We investigated if urine albumin levels normalised by creatinine give results comparable to the urinary albumin excretion rate (UAER) with a timed 24-h urine for detecting microalbuminuria. MATERIALS AND METHODS Morning urine specimens and 24-h collections were obtained from 65 diabetic patients. Albumin and creatinine levels in the spot urine specimens were measured in a single rapid (7 min) assay format using the Bayer DCA2000+ desktop system. Results of albumin/creatinine ratio and urine albumin concentration were then compared to the reference laboratory method of measuring UAER with the timed 24-h urine sample. RESULTS The determination of the albumin/creatinine ratio gave good performance characteristics for diagnosis of microalbuminuria (defined as > 30 mg/g creatinine) with sensitivity of 71.4% and specificity of 98.0%. With urine albumin concentration alone, sensitivity was 64.3% and specificity was 96.1%. Receiver operating characteristic (ROC) curves, however, suggest similar diagnostic usefulness for screening microalbuminuria with albumin levels expressed in concentration units or as a ratio of creatinine compared to the reference method. Analysis also indicated that lowering the established cut-off values in general, improves diagnostic performance. CONCLUSIONS Measurement of microalbuminuria with a spot morning specimen using the DCA2000+ desktop system that simultaneously measures albumin and creatinine levels, provides a rapid and reliable method for incipient diabetic nephropathy in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

Why 24-h Urine Albumin Excretion Rate Method Still is Used for Screening of Diabetic Nephropathy in Isfahan Laboratories?

BACKGROUND The first step in diagnosis of diabetic nephropathy is measurement of albumin in a spot urine sample. The aim of this study was assessment of the accuracy of urinary albumin to creatinine ratio (UACR) in random urine specimens (RUS) for microalbuminuria and macroalbuminuria screening in Iranian diabetic patients. METHODS A total of 200 diabetic patients participated to our study. 2...

متن کامل

The Effectiveness of the Semi-quantitative Assessment of Microalbuminuria Using Routine Urine Dipstick Screening in Patients with Diabetes

Objective The early diagnosis and treatment of microalbuminuria is important for preventing the progression of diabetic kidney disease in patients with diabetes. In this study, we assessed the accuracy of the semi-quantitative measurement of microalbuminuria by urine dipstick screening in patients with diabetes. Methods The semi-quantitative urinary albumin-to-creatinine ratio (QUACR) was used ...

متن کامل

Screening for diabetic microalbuminuria in routine clinical care: which method?

The measurement of albumin/creatinine ratios and simple albumin concentrations in early morning urine specimens were evaluated to establish which was the best screening test for those likely to have microalbuminuria by the reference standard analysis of timed overnight urine specimens. The measurement of an albumin/creatinine ratio with a cut off of > or = 2.0 mg/mmol was found to be suitable w...

متن کامل

Physical activity alters urinary albumin/ creatinine ratio in type 1 diabetic patient.

While the best way to identify microalbuminuria is to determine albumin excretion rate (AER) in a 24 h urine sample. Published data have shown that calculation of an albumin/creatinine ratio (ACR) in a spot urine sample has reasonable rate of sensitivity and specificity. We aimed to evaluate the effect of daily exercise on ACR and estimate the best time for the examination of the ACR in a spot ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2000