Pattern electroretinograms from hemifields in normal subjects and patients with glaucoma.

نویسندگان

  • S L Graham
  • V A Wong
  • S M Drance
  • F S Mikelberg
چکیده

PURPOSE Because glaucomatous visual field loss predominantly occurs in one hemifield, a baseline ratio of pattern electroretinogram (PERG) hemifield amplitudes (upper field:lower field) was determined in normal subjects and then examined in patients with glaucoma. METHODS In 26 normal subjects and eight patients with glaucoma with typical arcuate field loss involving the test area (central 20 degrees), hemifield PERGs were recorded using checkerboard screens of check size 0.5 degrees and frequency 3.75 reversals per second (transient) and 15 reversals per second (steady state). RESULTS The ratios obtained for normal central upper:lower amplitudes were 0.95 +/- 0.13 (transient) and 0.93 +/- 0.10 (steady state Fourier second harmonic). Wide nasal-field (52 degrees x 42 degrees) PERG ratios recorded on two subjects confirmed that the ratio held across large retinal areas. The ratio did not change with age or check size. The ratio showed less variability between patients than PERG amplitudes. In the patients with glaucoma, the hemifield PERG amplitude correlated with summed visual field thresholds for that area. Patients with glaucoma could be discriminated from normals by an abnormal ratio (> 2 SD) in seven of the eight patients. In two additional patients with more peripheral scotomas, the ratio remained normal. CONCLUSIONS In normals, the upper:lower hemifield PERG ratio is slightly < 1.0 and remains stable with age. In glaucoma, visual field defects are associated with PERG reductions in the corresponding hemifield. An abnormal PERG hemifield ratio can be found in many patients, although more peripheral and symmetrical losses may still be missed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pattern-reversal electroretinograms in unilateral glaucoma.

Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means...

متن کامل

S-cone, L+M-cone, and pattern, electroretinograms in ocular hypertension and glaucoma

Silent substitution and selective adaptation techniques were used to obtain full field S-cone and L + M-cone electroretinograms from 18 patients with ocular hypertension (OHT), 9 with normotensive glaucoma (NTG), 18 with early primary open angle glaucoma (POAG) and 19 normal controls. Pattern electroretinograms were also recorded, using a reduced check size to increase the contribution of retin...

متن کامل

Prevalence and nature of early glaucomatous defects in the central 10° of the visual field.

IMPORTANCE The macula is essential for visual functioning and is known to be affected even in early glaucoma. However, little is currently understood about the prevalence and nature of central vision loss in early glaucoma. OBJECTIVE To determine the prevalence and characteristics of visual field (VF) defects in the central 10° in glaucoma suspects and patients with mild glaucoma using a pros...

متن کامل

Dichoptic stimulation improves detection of glaucoma with multifocal visual evoked potentials.

PURPOSE To determine whether simultaneous binocular (dichoptic) stimulation for multifocal visual evoked potentials (mfVEP) detects glaucomatous defects and decreases intereye variability. METHODS Twenty-eight patients with glaucoma and 30 healthy subjects underwent mfVEP on monocular and dichoptic stimulation. Dichoptic stimulation was presented with the use of virtual reality goggles (recor...

متن کامل

Detection of glaucomatous damage in patients with osteo-odontokeratoprosthesis.

BACKGROUND Osteo-odontokeratoprosthesis (OOKP) is an autologous transplantation procedure in which the cornea is replaced by an optical cylinder glued to a biological support. Patients undergoing OOKP surgery may develop a secondary glaucoma whose diagnosis, by means of standard diagnostic procedures, is often doubtful. METHODS In the present study pattern electroretinograms (PERGs), visual e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1994