Performance of the XE-2100 leucocyte differential.

نویسندگان

  • G Stamminger
  • D Auch
  • H Diem
  • P Sinha
چکیده

The XE-2100 trade mark was evaluated in a multicentre study following a previously established protocol. In this paper, we demonstrate the results of analytical performance studies, including comparison of the leucocyte differential with the NCCLS H20-A method and evaluation of flagging sensitivity. Linearity of the leucocyte count over a wide clinical range, low imprecision in clinically important ranges and no measurable carry over were confirmed. For comparability studies, 4 x 200 cell microscopic differential leucocyte counts were correlated with the automated five-part-differential counts. No significant differences were detected in (1) a group without morphological abnormality and in (2) a leukopenic group. The sensitivity of flags for the detection of immature granulocytes and myeloid blasts was very good. Only few samples containing blast cells remained unrecognized but these would have been examined microscopically in any event because of other abnormalities indicated by the instrument. Atypical/abnormal lymphocytes/and lymphoblasts were detected very reliably when the total lymphocyte count and the flags were evaluated in combination. A similar procedure is recommended for the detection of left shift. When the neutrophil count is elevated, the sensitivity of the left shift flag is improved. The absolute immature granulocyte (IG) count by the instrument correlates well with that of myeloid precursor cells by microscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First basic performance evaluation of the XE-2100 haematology analyser

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K. Reproducibility, carryover, sta...

متن کامل

Performance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.

Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...

متن کامل

Performance characteristics of the Sysmex XT-2000i hematology analyzer.

The XT-2000i is a new hematology analyzer combining aperture impedance and optical technologies. It is capable of generating a 30-parameter hematologic assay on peripheral blood at a throughput of 80 samples per hour. We have evaluated the performance characteristics of the XT-2000i analyzer and compared them with those of the state-of-the-art XE-2100 analyzer and the manual differential count....

متن کامل

The New Sysmex XN-2000 Automated Blood Cell Analyzer More Accurately Measures the Absolute Number and the Proportion of Hematopoietic Stem and Progenitor Cells Than XE-2100 When Compared to Flow Cytometric Enumeration of CD34+ Cells

The gold standard to count circulating hematopoietic stem and progenitor cells (HPCs) is to enumerate CD34 cells by using flow cytometry [1, 2]. XE-2100 (Sysmex, Kobe, Japan), a currently used hematology analyzer, can be used to quantify HPCs, generating counts that reportedly correlate with those obtained using flow cytometric analysis of CD34 cells; however, XE-2100 HPC counts were 1.86-fold ...

متن کامل

Automated counting of white blood cells in synovial fluid.

OBJECTIVES To evaluate the performance of automated leucocyte (white blood cell; WBC) counting by comparison with manual counting. METHODS The number of WBC was determined in heparinized synovial fluid samples by the use of (i) a standard urine cytometer (Kova) and a microscope (reference method) and (ii) a haematology analyser (Sysmex XE-2100; WBC/BASO and DIFF channels). Imprecision within ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and laboratory haematology

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2002