Photo-Ionized Lithium Source for Plasma Accelerator Applications

نویسندگان

  • P. Muggli
  • K. A. Marsh
  • S. Wang
  • C. E. Clayton
  • S. Lee
  • T. C. Katsouleas
  • C. Joshi
چکیده

A photo-ionized lithium source is developed for plasma acceleration applications. A homogeneous column of lithium neutral vapor with a density of 2 10 cm 3 is confined by helium gas in a heat-pipe oven. A UV laser pulse ionizes the vapor. In this device, the length of the neutral vapor and plasma column is 25 cm. The plasma density was measured by laser interferometry in the visible on the lithium neutrals and by CO2 laser interferometry on the plasma electrons. The maximum measured plasma density was 2.9 10 cm , limited by the available UV fluence ( 83 mJ/cm), corresponding to a 15% ionization fraction. After ionization, the plasma density decreases by a factor of two in about 12 s. These results show that such a plasma source is scaleable to lengths of the order of 1 m and should satisfy all the requirements for demonstrating the acceleration of electrons by 1 GeV in a 1-GeV/m amplitude plasma wake.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma Wakefield Experiments at Facet*

FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to ~20μm long and focused to ~10μm wide. The intense fields of the FACET bunches will be used to field...

متن کامل

Plasma production via field ionization

Plasma production via field ionization occurs when an incoming particle beam is sufficiently dense that the electric field associated with the beam ionizes a neutral vapor or gas. Experiments conducted at the Stanford Linear Accelerator Center explore the threshold conditions necessary to induce field ionization by an electron beam in a neutral lithium vapor. By independently varying the transv...

متن کامل

Meter Long, Homogeneous Plasma Source for Advanced Accelerator Applications

A prototype for a l-meter long plasma source is developed for plasma acceleration experiments. The lithium neutral vapor with a density of 2×10 t5 cm 4 is ionized by a uv laser pulse and produces a plasma density of 2.6x10 ~4 cm 3. The plasma density is limited by the available uv energy. In this prototype, the length of the neutral vapor and plasma column is 25 cm. After ionization the plasma ...

متن کامل

Particle Beam Waist Location in Plasma Wakefield Acceleration

The role of beam waist location in interactions between a plasma and a particle beam is not yet fully understood. Nonlinear effects with the plasma make an analysis of such interactions difficult. Five simulations are presented in this report, with the waist location of a beam of ultra-relativistic electrons propagating through one meter of self-ionized lithium plasma. The simulation parameters...

متن کامل

Meter Scale Plasma Source For Plasma Wakefield Experiments

High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999