The Ross Procedure

نویسندگان

  • Pieter E. Zondervan
  • Jolien W. Roos-Hesselink
  • Magdi H. Yacoub
چکیده

Background—Reports on outcome after the Ross procedure are limited by small study size and show variable durability results. A systematic review of evidence on outcome after the Ross procedure may improve insight into outcome and potential determinants. Methods and Results—A systematic review of reports published from January 2000 to January 2008 on outcome after the Ross procedure was undertaken. Thirty-nine articles meeting the inclusion criteria were allocated to 3 categories: (1) consecutive series, (2) adult patient series, and (3) pediatric patient series. With the use of an inverse variance approach, pooled morbidity and mortality rates were obtained. Pooled early mortality for consecutive, adult, and pediatric patients series was 3.0% (95% confidence interval [CI], 1.8 to 4.9), 3.2% (95% CI, 1.5 to 6.6), and 4.2% (95% CI, 1.4 to 11.5). Autograft deterioration rates were 1.15% (95% CI, 1.06 to 2.06), 0.78% (95% CI, 0.43 to 1.40), and 1.38%/patient-year (95% CI, 0.68 to 2.80), respectively, and for right ventricular outflow tract conduit were 0.91% (95% CI, 0.56 to 1.47), 0.55% (95% CI, 0.26 to 1.17), and 1.60%/patient-year (95% CI, 0.84 to 3.05), respectively. For studies with mean patient age 18 years versus mean patient age 18 years, pooled autograft and right ventricular outflow tract deterioration rates were 1.14% (95% CI, 0.83 to 1.57) versus 1.69% (95% CI, 1.02 to 2.79) and 0.65% (95% CI, 0.41 to 1.02) versus 1.66%/patient-year (95% CI, 0.98 to 2.82), respectively. Conclusions—The Ross procedure provides satisfactory results for both children and young adults. Durability limitations become apparent by the end of the first postoperative decade, in particular in younger patients. (Circulation. 2009;119: 222-228.)

منابع مشابه

عوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross

Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...

متن کامل

Long-Term Outcomes of the Ross Procedure Versus Mechanical Aortic Valve Replacement: Propensity-Matched Cohort Study.

BACKGROUND The ideal aortic valve substitute in young and middle-aged adults remains unknown. We sought to compare the long-term outcomes of patients undergoing the Ross procedure and those receiving a mechanical aortic valve replacement (AVR). METHODS From 1990 to 2014, 258 patients underwent a Ross procedure and 1444 had a mechanical AVR at a single institution. Patients were matched into 2...

متن کامل

Long-term results of the Ross procedure in a population-based follow-up.

OBJECTIVES The purpose of this study was to evaluate the long-term outcomes of the Ross procedure in a nationwide follow-up. METHODS This retrospective study involved all children treated with the Ross procedure in Finland between 1994 and 2009. The clinical records were reviewed for demographic and anatomical characteristics, Ross operation data, surgical history and status at the latest fol...

متن کامل

Cardiovascular Surgery Survival Comparison of the Ross Procedure and Mechanical Valve Replacement With Optimal Self-Management Anticoagulation Therapy Propensity-Matched Cohort Study

Background—It is suggested that in young adults the Ross procedure results in better late patient survival compared with mechanical prosthesis implantation. We performed a propensity score–matched study that assessed late survival in young adult patients after a Ross procedure versus that after mechanical aortic valve replacement with optimal self-management anticoagulation therapy. Methods and...

متن کامل

The Ross procedure: shorter hospital stay, decreased morbidity, and cost effective.

BACKGROUND The Ross procedure has become an accepted and sometimes preferred alternative to mechanical aortic valve replacement. One criticism of the Ross procedure is that it may have a higher operative mortality, morbidity, and cost. Several groups have shown that this operation can be performed safely with less than 3% mortality. The issue of higher cost has not been resolved. In this retros...

متن کامل

Survival comparison of the Ross procedure and mechanical valve replacement with optimal self-management anticoagulation therapy: propensity-matched cohort study.

BACKGROUND It is suggested that in young adults the Ross procedure results in better late patient survival compared with mechanical prosthesis implantation. We performed a propensity score-matched study that assessed late survival in young adult patients after a Ross procedure versus that after mechanical aortic valve replacement with optimal self-management anticoagulation therapy. METHODS A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009