Functional Validation and Comparison Framework for EIT Lung Imaging

نویسندگان

  • Bartłomiej Grychtol
  • Gunnar Elke
  • Patrick Meybohm
  • Norbert Weiler
  • Inéz Frerichs
  • Andy Adler
چکیده

INTRODUCTION Electrical impedance tomography (EIT) is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen). In this way, large and discrete shifts in global and regional lung air content were elicited. METHODS We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm), GREIT (a more recent consensus algorithm for lung imaging), truncated singular value decomposition (TSVD), several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV) reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data. RESULTS AND CONCLUSIONS Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mutual information as a measure of image quality for 3D dynamic lung imaging with EIT.

We report on a pilot study of dynamic lung electrical impedance tomography (EIT) at the University of Manchester. Low-noise EIT data at 100 frames per second were obtained from healthy male subjects during controlled breathing, followed by magnetic resonance imaging (MRI) subsequently used for spatial validation of the EIT reconstruction. The torso surface in the MR image and electrode position...

متن کامل

Dynamic functional EIT Imaging (df-EIT) – A New Concept for Monitoring Effects on regional Lung Function induced by Respiratory Therapy

EIT can potentially offer useful information for monitoring regional lung function directly at the bedside. However it is not evident which presentation of this information is most suitable for monitoring and how this can be efficiently achieved. Using a conventional EIT movie interpretation is inherently difficult due to the continuously changing image. We propose a novel monitoring method of ...

متن کامل

Software and Operational Concept for EIT-Based regional lung Function monitoring

Electrical Impedance Tomography (EIT) is a non-invasive imaging technique suitable for medical application. Most of the previous investigations have been done under laboratory conditions and only few projects under real hospital environment. This paper presents a novel concept of EIT application for clinical lung ventilation monitoring. A virtual EIT lung ventilation monitor suitable for applic...

متن کامل

Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs.

STUDY OBJECTIVE The validation of electrical impedance tomography (EIT) for measuring regional ventilation distribution by comparing it with single photon emission CT (SPECT) scanning. DESIGN Randomized, prospective animal study. SETTINGS Animal laboratories and nuclear medicine laboratories at a university hospital. PARTICIPANTS Twelve anesthetized and mechanically ventilated pigs. INT...

متن کامل

Tracking boundary movement and exterior shape modelling in lung EIT imaging.

Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comparison of these approaches is available. This paper analyses boundary model mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014