Investigations of an automatic screening device (MESAM) for obstructive sleep apnoea.

نویسندگان

  • R Stoohs
  • C Guilleminault
چکیده

A digital recording device developed to monitor heart rate (HR) and breathing sounds (snoring), and used to screen subjects for obstructive sleep apnoea syndrome (OSAS), was investigated. This device is called the MESAM and is currently commercially available in some western European countries. The computer-based automatic scoring systems provided with the equipment and a hand-scoring technique developed at Stanford and requiring 10-15 min to perform, were used. Polysomnography and MESAM recordings were performed simultaneously on two groups of 25 sleep disorder patients (each with respiratory disturbance index greater than or less than 10). Patients were randomly monitored and records were analysed by two teams blind to the initial clinical impression, to the events which occurred during the recordings, and to each other's findings. Specificity and sensitivity were calculated for each of the MESAM scoring techniques considered, with polysomnography being selected as the recording standard, With "automatic HR scoring" specificity was 12%, sensitivity 92%; with "automatic breathing sounds (snoring)" scoring, specificity was 8% and sensitivity 96%; with "hand-scoring" specificity was 72% and sensitivity 92%. If the three scoring techniques were combined, all patients with a respiratory disturbance index (RD) greater than 10 were recognized as having OSAS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea.

The MESAM 4 system, developed to monitor breathing sounds, heart rate, arterial oxygen saturation (Sao2) and body position, was proposed as a screening method for obstructive sleep apnoea (OSA). The aim of the study was to assess the accuracy of hand-scoring versus automatic-scoring in screening for obstructive sleep apnoea. The study population consisted of 56 patients, 51 males, and 5 females...

متن کامل

Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea.

This study evaluated the accuracy of a portable recording device (MESAM IV) in identifying obstructive sleep apnoea (OSA). The MESAM IV system measures arterial oxygen saturation (Sa,O2), heart rate, snoring sounds and body position, and allows both automatic and manual scoring of the recordings. Nocturnal polysomnography and MESAM IV recordings were performed simultaneously in 150 patients wit...

متن کامل

Quantification of sleep disordered breathing by computerized analysis of oximetry, heart rate and snoring.

Intermittent snoring and cyclic oscillations of heart rate and oxyhaemoglobin saturation (Sao2) are characteristic features of the obstructive sleep apnoea syndrome (OSAS). Thus, overnight recordings of laryngeal sounds and heart rate by a portable device (MESAM) and of Sao2 by oximetry are applicable to screen outpatients for the presence of OSAS. Computerized analysis for time intervals of co...

متن کامل

Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome.

The current study investigated the night-to-night variability and diagnostic accuracy of the oxygen desaturation index (ODI), as measured by ambulatory monitoring, in the diagnosis of mild and moderate obstructive sleep apnoea-hypopnoea syndrome. To assess the variability of the ODI, 35 patients were monitored at home during 7 consecutive nights by means of a portable recording device, the MESA...

متن کامل

Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome.

BACKGROUND Portable devices are used for unattended recording of patients with suspected obstructive sleep apnea syndrome (OSAS). The MESAM 4 (MAP; Martinsried, Germany) is a computerized ambulatory polysomnographic system that records four parameters: breathing noise, heart rate, arterial oxygen saturation (SaO(2)), and body position. DESIGN AND METHOD We evaluated the reliability of the oxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 3 7  شماره 

صفحات  -

تاریخ انتشار 1990