An in vivo study of working length determination with a new apex locator.

نویسندگان

  • Key Fabiano Souza Pereira
  • Pedro Gregol da Silva
  • Fabio Simões de Vicente
  • Fabio Nakao Arashiro
  • Carmem Regina Coldebella
  • Carlos Alberto Spironelli Ramos
چکیده

The success of an endodontic treatment relies on a correct working length determination. The canal terminus must be detected accurately and a precise control of the working length during the endodontic treatment must be maintained. The aim of this study was to investigate the working length determination in vivo with the Quill Apex Locator® for apical limit established at 1 mm short from the apical foramen (AF). Patients scheduled to dental extraction due to orthodontic or periodontal reasons were selected for this study, resulting in a sample of 24 root canals. Written informed consent was obtained from each patient before the treatment. After the administration of local anesthesia each tooth had its pulp cavity accessed. Next, the reading corresponding to the AF showed on the device's display was recorded and the file was removed. With the use of a digital caliper, 1 mm was subtracted from that first measurement. The file with the new measurement was introduced into to the root canal again then fixed with light curing flow composite and the tooth was extracted. Next, one of the apical third walls was worn out to visualize the instrument's point and the AF. The distance from the file tip to the AF was measured by scanning electron microscopy. The average of the measurements was 1.089±0.437 mm. The Bicaudal t-test showed no significant difference (p=0.338) between the experimental values and the hypothetical value tested at 1 mm. The present investigation confirmed that the Quill Apex Locator® was able to determine the working length with good reliability for the endodontic treatment, established at 1 mm short from the AF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)

Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

ارزیابی دقت یک نوع Electronic Apex Locator  در تعیین طول دندانهای شیری (In-vitro)

Statement of Problem: Radiography is the most common technique in working length determination, however, because of its limitations is not considered as an ideal technique. Its application, particularly for children due to radiation hazards, technical problems in young and unco-operative children and the superimposition of permanent teeth bud on primary teeth root, lead to numerous problems.Pur...

متن کامل

ارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول کانال دندانهای شیری در شرایط In vivo

Background and Aim: Radiography is the most commonly used technique in root canal length determination, but its application in pedodontics is difficult due to many problems such as radiation hazards, superimposition of permanent teeth buds and uncooperative children. The aim of this study was to investigate the accuracy of an electronic apex locator (Dentaport ZX) in measuring the root canal le...

متن کامل

مقایسه کلینیکی دقت اپکس یاب الکترونیکی و رادیوگرافی در تعیین طول کانال ریشه در دندان‌های مولر شیری

Introduction: Radiography is the most common method for measurement of working length, though it is not the ideal method because of technical problems, radiation hazard, superimposition of permanent teeth bud on primary teeth, and so on. Electronic Apex Locator (EAL) is a device for determination of working length. Therefore, this study aimed to compare the accuracy of an electronic apex locato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 2014