Myocardial uptake of 7'-(Z)-[(123)I]iodorotenone during vasodilator stress in dogs with critical coronary stenoses.

نویسندگان

  • Alexis Broisat
  • Mirta Ruiz
  • Norman C Goodman
  • Stephen M Hanrahan
  • Bryan W Reutter
  • Kathleen M Brennan
  • Mustafa Janabi
  • Saul Schaefer
  • Denny D Watson
  • George A Beller
  • Henry F VanBrocklin
  • David K Glover
چکیده

BACKGROUND There is a well-recognized need for a new generation of single photon emission computed tomography (SPECT) perfusion tracers with improved myocardial extraction over a wide flow range. Radiotracers that target complex I of the mitochondrial electron transport chain have been proposed as a new class of myocardial perfusion imaging agents. 7-(Z)-[(125)I]iodorotenone ((125)I-ZIROT) has demonstrated superior myocardial extraction and retention characteristics in rats and in isolated perfused rabbit hearts. We sought to fully characterize the biodistribution and myocardial extraction versus flow relationship of (123)I-ZIROT in an intact large-animal model. METHODS AND RESULTS The (123)I-ZIROT was administered during adenosine A(2A) agonist-induced hyperemia in 5 anesthetized dogs with critical left anterior descending (LAD) stenoses. When left circumflex (LCx) flow was maximal, (123)I-ZIROT and microspheres were coinjected and the dogs were euthanized 5 minutes later. (123)I-ZIROT biodistribution was evaluated in 2 additional dogs by in vivo planar imaging. At (123)I-ZIROT injection, transmural LAD flow was unchanged from baseline (mean±SEM, 0.90±0.22 versus 0.87±0.11 mL/[min · g]; P=0.92), whereas LCx zone flow increased significantly (mean±SEM, 3.25±0.51 versus 1.00±0.17 mL/[min · g]; P<0.05). Myocardial (123)I-ZIROT extraction tracked regional myocardial flow better than either thallium-201 or (99m)Tc-sestamibi from previous studies using a similar model. Furthermore, the (123)I-ZIROT LAD/LCx activity ratios by ex vivo imaging or well counting (mean±SEM, 0.42±0.08 and 0.45±0.1, respectively) only slightly underestimated the LAD/LCx microsphere flow ratio (0.32±0.09). CONCLUSIONS The ability of (123)I-ZIROT to more linearly track blood flow over a wide range makes it a promising new SPECT myocardial perfusion imaging agent with potential for improved coronary artery disease detection and better quantitative estimation of the severity of flow impairment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fractional Flow Reserve Assessment With Demand Stress Myocardial Contrast Echocardiography in Angiographically Intermediate Coronary Stenoses.

BACKGROUND Real-time myocardial contrast echocardiography (RTMCE) directly measures capillary flow (CBF), which in turn is a major regulator of coronary flow and resistance during demand or hyperemic stress. Although fractional flow reserve (FFR) was developed to assess the physiological relevance of an epicardial stenosis, it assumes maximal microvascular vasodilation and minimal resistance du...

متن کامل

Comparison With Adenosine Stress

Background—The myocardial uptake of Tc-sestamibi is attenuated by dobutamine stress, resulting in underestimation of ischemia. N-Ethyl-N-ethoxy-dithiocarbamato-N-Tc (Tc-N-NOET) is a new Tc-labeled perfusion agent that is highly extracted by the myocardium by a mechanism different from that defined for Tc-sestamibi. We therefore hypothesized that Tc-N-NOET uptake would not be attenuated by dobut...

متن کامل

Mechanism of reversible (99m)Tc-sestamibi perfusion defects during pharmacologically induced vasodilatation.

Reversible perfusion defects on (99m)Tc-sestamibi imaging during hyperemia are thought to occur due to myocardial blood flow (MBF) "mismatch" between regions with and without stenosis. We have recently shown that myocardial blood volume (MBV) distal to a stenosis decreases during hyperemia, resulting in a reversible perfusion defect on myocardial contrast echocardiography (MCE). In this study, ...

متن کامل

Mechanism of reversible Tc-sestamibi perfusion defects during pharmacologically induced vasodilatation

Wei, Kevin, Elizabeth Le, Jian-Ping Bin, Matthew Coggins, Ananda R. Jayawera, and Sanjiv Kaul. Mechanism of reversible Tc-sestamibi perfusion defects during pharmacologically induced vasodilatation. Am J Physiol Heart Circ Physiol 280: H1896–H1904, 2001.—Reversible perfusion defects on Tc-sestamibi imaging during hyperemia are thought to occur due to myocardial blood flow (MBF) “mismatch” betwe...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 2011