Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.

نویسندگان

  • Gregor Brüllmann
  • Karsten Fritsch
  • Robert Thurnheer
  • Konrad E Bloch
چکیده

BACKGROUND Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor feedback. METHODS Five healthy subjects and 12 patients with lung disease were monitored by portable RIP with sensors incorporated within a body garment. Unrestrained individuals were studied during 40-60 min while supine, sitting and upright/walking. Position was changed repeatedly every 5-10 min. Initial qualitative diagnostic calibration followed by volume scaling in absolute units during 20 breaths in different positions by flow meter provided position-specific volume-motion coefficients for RIP. These were applied during subsequent monitoring in corresponding positions according to feedback from 4 accelerometers placed at the chest and thigh. Accuracy of RIP was evaluated by face mask pneumotachography. RESULTS Position sensor feedback allowed accurate adjustment of RIP calibration during repeated position changes in subjects and patients as reflected in a minor mean difference (bias) in breath-by-breath tidal volumes estimated by RIP and flow meter of 0.02 liters (not significant) and limits of agreement (+/-2 SD) of +/-19% (2,917 comparisons). An average of 10 breaths improved precision of RIP (limits of agreement +/-14%). CONCLUSIONS RIP calibration incorporating position sensor feedback greatly enhances the application of RIP as a valuable, unobtrusive tool to investigate respiratory physiology and ventilatory limitation in unrestrained healthy subjects and patients with lung disease during everyday activities including position changes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of respiratory inductive plethysmography in patients with pulmonary disease.

The assumption that the respiratory system behaves with 2 df of motion in healthy persons allows calibration of respiratory inductive plethysmography (RIP) with spirometry (SP). To ascertain whether RIP could be calibrated by the same assumption in patients with lung disease, even though at least 3 df of motion are visualized (ie, upper and lower rib cage and upper and lower abdomen move out of...

متن کامل

Respiratory inductive plethysmography: a comparative study between isovolume maneuver calibration and qualitative diagnostic calibration in healthy volunteers assessed in different positions.

OBJECTIVE To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. METHODS We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 ± 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. I...

متن کامل

Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.

STUDY OBJECTIVE To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN An open comparison between two methods using a criterion standard. E...

متن کامل

Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs.

Respiratory inductive plethysmography (RIP) can measure breathing patterns noninvasively. Calibration is required for rib cage and abdomen transducers utilizing breaths with different compartment contribution correlated with tidal volume measured by integrated pneumotachography (PNT). This study was performed to determine if RIP remains accurate during sleep states following calibration in the ...

متن کامل

A device for 24 hour ambulatory monitoring of abdominal girth using inductive plethysmography.

Inductive plethysmography (IP) sensors and oscillator modules were assessed for their potential use in the ambulatory monitoring of abdominal girth in subjects with irritable bowel syndrome (IBS) in order to objectively quantify their bloating symptoms. A dedicated microprocessordata logger was designed to record over 24 h the frequency output of IP oscillators connected to a belt around the su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 79 2  شماره 

صفحات  -

تاریخ انتشار 2010