Scintigraphic assessment of radio-aerosol pulmonary deposition with the acapella positive expiratory pressure device and various nebulizer configurations.
نویسندگان
چکیده
BACKGROUND The Acapella device produces high-frequency oscillations and positive expiratory pressure to promote bronchial secretion clearance. Its performance during aerosol delivery has not been described. We evaluated the effect of nebulizer and Acapella configuration on pulmonary deposition of radio-tagged aerosol in healthy subjects. METHODS Ten healthy male subjects (mean age 24.4 ± 2.2 y) participated in a crossover study that compared pulmonary delivery of 4 mL of technetium-99m-labeled diethylene triamine penta-acetic acid (25 mCi) and 0.9% saline solution via jet nebulizer. We tested 3 configurations: nebulizer attached to the distal end of the Acapella; nebulizer placed between the mouthpiece and the Acapella; and nebulizer alone (control). With scintigraphy we measured radio-aerosol deposition in 6 lung regions: upper, middle, lower, central, intermediate, and peripheral. RESULTS Deposition was similar between the right and left lungs, with no significant differences between device configurations. Lung deposition was less with the nebulizer attached to the Acapella than with nebulizer between the mouthpiece and the Acapella (P = .001, for both lungs) or without the Acapella (P = .003 and P = .001 for the right and left lungs, respectively). There was no significant difference between the setup without Acapella and the setup with the nebulizer between the mouthpiece and the Acapella (P = .001, for both lungs). On the vertical axis, deposition was lower with the nebulizer attached to the distal end of the Acapella than with the nebulizer between the mouthpiece and the Acapella (upper region P < .001, middle region P = .001, lower region P = .003), and lower with the nebulizer attached to the distal end of the Acapella than with the setup without Acapella (upper and middle region both P = .001, lower region P = .002), with up to a 3-fold difference in the middle and lower regions. On the central-peripheral axis, deposition was lower with the nebulizer attached to the distal end of the Acapella than with the nebulizer between the mouthpiece and the Acapella (central region P < .001, peripheral region P < .001), and lower with the nebulizer attached to the distal end of the Acapella than with the setup without Acapella (central and peripheral regions both P = .002), with differences of 3-4-fold between the central and peripheral regions. CONCLUSIONS Placing the nebulizer distal to the Acapella, as recommended by the manufacturer, decreased intrapulmonary deposition, compared to placing the nebulizer between the Acapella and the patient airway, or delivering aerosol without the Acapella in the circuit. (ClinicalTrials.gov NCT01102166).
منابع مشابه
In vitro evaluation of positive expiratory pressure devices attached to nebulizers.
BACKGROUND Patients with cystic fibrosis perform airway clearance techniques and receive nebulized medications on a regular basis. Some positive expiratory pressure (PEP) devices allow concomitant administration of aerosol. I hypothesized that this practice alters the aerosol characteristics and patient dose. I compared the aerosol characteristics and patient dose of nebulized albuterol from 2 ...
متن کاملNoninvasive ventilation coupled with nebulization during asthma crises: a randomized controlled trial.
BACKGROUND Despite the clinical improvements attributed to noninvasive ventilation (NIV) during asthma crises, and the well established effects of nebulization, there are few studies on the effects of these interventions together. We hypothesized that nebulization coupled to NIV should raise radio-aerosol pulmonary deposition in asthmatics. The aims of this study were to assess the effects of c...
متن کاملPositive expiratory pressure changes aerosol distribution in patients with cystic fibrosis.
HYPOTHESIS We hypothesized that aerosol distribution in the lungs of patients with cystic fibrosis changes with positive expiratory pressure (PEP). METHODS Eight patients were randomized to one of 2 conditions. On one study day, patients inhaled saline aerosol containing 99mtechnetium generated by a Pari LC Plus nebulizer and exhaled through a Pari PEP device. On another day, the same patient...
متن کاملResponse of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملPerformance comparison of two oscillating positive expiratory pressure devices: Acapella versus Flutter.
BACKGROUND Oscillatory positive expiratory pressure (PEP) with the Flutter device facilitates secretion removal. In the Flutter a steel ball vibrates inside a cone, causing air flow vibration. A new device, the Acapella, uses a counterweighted plug and magnet to create air flow oscillation. The Acapella comes in 2 models: one for patients with expiratory flow > or = 15 L/min and one for < or = ...