Studies on optimization of radiation protection for patients in diagnostic radiology
نویسنده
چکیده
For the exposure of patients in diagnostic radiology, individual dose limit does not apply, but optimization of radiological protection may play a major role. This project has been carried out with the purpose of improving the protection of patients in medical diagnostic radiology in China utilizing the principles of optimization. Taking Sichuan, Shandong and Beijing as surveyed areas, we investigated the present situation of the protection of patients. In the survey, the patient doses were classified into practical dose, justified dose and optimized dose to evaluate the influences of managerial and equipment factors separately. The results show that there are some urgent protection problems in X-ray protection to be solved in the surveyed regions. This paper, however, points out that the prospects of reducing patient doses are encouraging provided that appropriate measures are adopted. For instance, taking proper managerial measures without radical change of existing equipments may reduce patient doses in chest fluoroscopy and radiography by 40% and 18% respectively ; refitting some equipment may reduce the doses by 82.4% in chest fluoroscospy, 66% in chest radiography, and 80% in barium meal examination of the gastrointestinal (GI ) tract. Using chest radiography instead of fluoroscopy supplemented by other protection measures may reduce the doses by 91.7%. Optimization analysis shows that adoption of the above measures conforms to the principle of optimization of radiation protection. RÉSUMÉ Si, dans le cas du radiodiagnostic, les limites de dose individuelles ne s'appliquent pas à l'exposition des patients, l'optimisation de la radioprotection peut, par contre, jouer un rôle important. L'utilisation du principe d'optimisation a guidé ce projet visant à améliorer, en Chine, la protection des patients lors de la pratique du radiodiagnostic médical. Notre enquête, réalisée dans les régions de Sichuan, Shandong et Pékin (Chine), a évalué la situation actuelle de la protection des patients. Les doses aux patients ont été classées en dose réelle, dose justifiée et dose optimisée afin d'évaluer séparément l'influence des facteurs de * Laboratory of industrial hygiene, Ministry of public health, 2 Xinkang street, PO Box 8018, Beijing 100088, P.R. China. ** Institute of radiation medicine, Shandong Academy of medical sciences, Jinan 250001, P.R. China. *** Sichuan Institute of radiation health protection, Chengdu 610041, P.R. China. **** Beijing Institute of radiation health protection, Beijing 100013, P.R. China. RADIOPROTECTION VOL. 29 0033-8451/1994/11/$ 5.00/© Les Editions de Physique 201
منابع مشابه
بررسی وضعیت حفاظت در برابر پرتوهای یونیزان در مراکز پرتو تشخیصی ایران: مرور سیستماتیک مقالات منتشر شده
Background and purpose: Increasing number of patients undergoing x-ray examinations has created a global concern due to the deleterious biological effects associated with x-ray exposure. Adherence to ionizing radiation protection principles could be of great benefit in decreasing these effects. Accordingly, the aim of this study was to survey radiation protection in diagnostic x-ray imaging in ...
متن کاملOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...
متن کاملEvaluation of the Level of Protection in Radiology Departments of Kermanshah, Iran
Introduction Radiation protection is an important safety issue for radiographers and patients. The aim of this study was to assess the observance of radiation protection regulations in radiology departments of Kermanshah University of Medical Sciences, Kermanshah, Iran. Materials and Methods In total, 48 radiographers and 8 radiography rooms were evaluated in three hospitals of Kermanshah, Iran...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی
Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...
متن کاملEvaluation of radiation protection principles observance in radiology departments of Semnan University of medical sciences
Introduction: Most of people are exposed to ionizing radiation sources during their lifetime including background, cosmic or man-made beams like radiation used in nuclear medicine and radiology. Due to unavoidable use of ionizing radiation in diagnosis and treatment of diseases, designing and correct implementation of radiation protection principles in order to reducing its har...
متن کامل