Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans

نویسندگان

  • Sebastian Berisha
  • Joyce Han
  • Mohammed Shahid
  • Yuchi Han
  • Walter R. T. Witschey
چکیده

PURPOSE To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans. MATERIALS AND METHODS We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM). RESULTS In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85-0.97). Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T1ρ relaxation times in patients. CONCLUSION Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images

Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

Detection of Outliers and Influential Observations in Linear Ridge Measurement Error Models with Stochastic Linear Restrictions

The aim of this paper is to propose some diagnostic methods in linear ridge measurement error models with stochastic linear restrictions using the corrected likelihood. Based on the bias-corrected estimation of model parameters, diagnostic measures are developed to identify outlying and influential observations. In addition, we derive the corrected score test statistic for outliers detection ba...

متن کامل

Development of in vivo multi-slice spiral T1rho mapping in cartilage at 3T and its application to osteoarthritis

X. Li, E. T. Han, J. C. Crane, T. M. Link, B. Ma, G. Blumenkrantz, K. Keshari, D. C. Newitt, S. Majumdar MQIR, Department of Radiology, University of California at San Francisco, San Francisco, CA, United States, Applied Science Lab West, GE Healthcare, Menlo Park, CA, United States, Department of Radiology, University of California at San Francisco, San Francisco, CA, United States, Department...

متن کامل

Comparison of T1rho and T2 Mapping of Knee Articular Cartilage in an Asymptomatic Population

OBJECTIVE To analyze subregional differences in T1rho (T1ρ) and T2 values and their correlation in asymptomatic knee cartilage, and to evaluate angular dependence with magic angles. MATERIALS AND METHODS Six asymptomatic volunteers underwent knee MRI with T1ρ and T2 mapping. T1ρ and T2 values were measured by two radiologists independently, at nine subregions in the medial femoral condyle (MF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016