SLC Final Performance and Lessons

نویسنده

  • Nan Phinney
چکیده

The Stanford Linear Collider (SLC) was the first prototype of a new type of accelerator, the electronpositron linear collider. Many years of dedicated effort were required to understand the physics of this new technology and to develop the techniques for maximizing performance. Key issues were emittance dilution, stability, final beam optimization and background control. Precision, non-invasive diagnostics were required to measure and monitor the beams throughout the machine. Beam-based feedback systems were needed to stabilize energy, trajectory, intensity and the final beam size at the interaction point. A variety of new tuning techniques were developed to correct for residual optical or alignment errors. The final focus system underwent a series of refinements in order to deliver sub-micron size beams. It also took many iterations to understand the sources of backgrounds and develop the methods to control them. The benefit from this accumulated experience was seen in the performance of the SLC during its final run in 1997-98. The luminosity increased by a factor of three to 3*10 and the 350,000 Z data sample delivered was nearly double that from all previous runs combined.

منابع مشابه

ar X iv : p hy si cs / 0 01 00 08 3 O ct 2 00 0 SLC Final Performance and Lessons

The Stanford Linear Collider (SLC) was the first prototype of a new type of accelerator, the electronpositron linear collider. Many years of dedicated effort were required to understand the physics of this new technology and to develop the techniques for maximizing performance. Key issues were emittance dilution, stability, final beam optimization and background control. Precision, non-invasive...

متن کامل

Requirements for Linear Collider Instrumentation

Instrumentation performs a critical role in the operation of a linear collider. New acquisition and data processing techniques are required for feedback, tuning procedures and performance monitoring. For example, many collider systems are initially tuned using complex bootstrap procedures whose convergence rate will depend on the speed and performance of several instrumentation systems. Further...

متن کامل

What’s Needed to Develop Strategic Purchasing in Healthcare? Policy Lessons from a Realist Review

Background In the context of serious concerns over the affordability of healthcare, various authors and international policy bodies advise that strategic purchasing is a key means of improving health system performance. Such advice is typically informed by theories from the economics of organization (EOO). This paper proposes that these theories are insufficient for a full understanding o...

متن کامل

The Steered Auxiliary Beam Canceller for Interference Cancellation in a Phased Array

A common problem encountered in phased array signal processing is how to remove sources of interference from a desired signal. Two existing methods to accomplish this are the Linearly Constrained Minimum Variance (LCMV) beamformer and the Side-Lobe Canceller (SLC). LCMV provides better performance than SLC, but comes with much higher computational costs. The Steered Auxiliary Beam Canceller (SA...

متن کامل

Collimator Wake Fields in the Slc Final Focus*

The SLC final-focus system accommodates 29 fixed or adjustable collimators for machine protection and background reduction. By amplifying pulse-to-pulse orbit variations and by generating emittance growth, collimator wake fields may degrade the beam quality at the interaction point (IP). In the SLC final focus, collimator halfapertures are larger than the bunch length, so that the standard coll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000