Inter- and intraobserver variability of (99m)Tc-DMSA renal scintigraphy: impact of oblique views.

نویسندگان

  • Meltem Caglar
  • Pinar Ozgen Kiratli
  • Erdem Karabulut
چکیده

UNLABELLED (99m)Tc-Dimercaptosuccinic acid (DMSA) scintigraphy is a frequently used diagnostic test to assess the presence and severity of cortical damage. The aim of this study is to investigate the variability in the interpretation of (99m)Tc-DMSA scans, evaluate the usefulness of oblique images, and assess their impact on scan interpretation. METHODS Two experienced nuclear medicine physicians independently interpreted 100 (99m)Tc-DMSA scans (197 kidneys) 4 times. Interpretation was twice based on posterior projection images and twice based on posterior and posterior oblique projection images. For each kidney, the observers had to choose between the following results: normal, abnormal, and indeterminate. The indices of variability used were the percentage of agreement, kappa-statistic, and marginal homogeneity. RESULTS Intraobserver and interobserver reproducibility (kappa-values) varied between 0.683 and 0.708 and between 0.609 and 0.671, respectively, for posterior images. Disagreement in (99m)Tc-DMSA scan interpretation occurred in 18% of kidneys within observers and in 21% of kidneys between observers when only posterior images were used. Oblique views changed the interpretation in 14% and 11.5% of kidneys for the first and second observers, respectively. The use of oblique views increased the agreement rate within and between observers (kappa-values, 0.725-0.812 and 0.768-0.732, respectively; mean agreement, 86.5 and 87.25, respectively). CONCLUSION Oblique views were found useful in approximately 13% of kidneys and affected inter- and intraobserver variability. Our results suggest that oblique views should be used routinely in children with clinically suspected urinary tract infection to reliably interpret images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

use of 99m Tc-DMSA scintigraphy in assessment of renal complications of COVID-19

 ABSTRACT COVID-19 mainly affects respiratory and immune systems, but other organs like renal, cardiovascular, lung and nervous systems could also be involved in both acute and chronic settings (1, 2). There is a lot of studies that demonstrate an increasing number of long COVID-19 who continue to experience persistent symptoms weeks or even months after the initial disease. Reports suggest...

متن کامل

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction:The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar ima...

متن کامل

Pancake kidney: An unusual type of renal fusion anomaly found in 99mTc-DMSA renal scintigraphy

A 2.5-year-old boy with a history of the previous incidental finding of an ectopic kidney in ultrasonography was referred to our nuclear medicine center for 99mTc-DMSA renal scintigraphy. The scan showed an unusual type of ectopic fused kidneys on the right side of the lower abdomen. In this anomaly, kidneys were fused completely across the medial portion of both upper and lower pole...

متن کامل

A large renal pelvic diverticulum, presenting incomplete excretion during tc-99m MAG-3 scintigraphy and tracer accumulation on tc-99m DMSA scintigraphy; a case report.

This case report illustrates the dynamic and static renal scintigraphic images of a patient with an unusual large diverticulum of the renal pelvis. The initial diagnosis by intravenous pyelography (IVP) and ultrasonographic (US) examination was a renal pelvic diverticulum of the left kidney, and the patient was referred to the nuclear medicine department for exploration of the effect of the pel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2007