Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry.
نویسندگان
چکیده
Dual-energy X-ray absorptiometry (DEXA) is reported to be inferior to computed tomography (CT) to measure changes in appendicular soft tissue composition. We compared CT- and DEXA-measured thigh muscle and fat mass to evaluate the random and systematic discrepancies between these two methods. Thigh skeletal muscle area (single-slice CT) was suboptimally (r(2) = 0.74, P < 0.0001) related to DEXA-measured thigh fat-free mass (FFM). In contrast, thigh muscle and adipose tissue volumes (multislice CT) were highly related to DEXA-measured thigh FFM and fat (both r(2) = 0.96, P < 0.0001). DEXA-measured leg fat was significantly less than multislice-CT-measured leg adipose tissue volume, whereas multislice-CT-measured leg muscle mass was less (P < 0.0001) than DEXA-measured leg FFM. The systematic discrepancies between the two approaches were consistent with the 10-15% nonfat components of adipose tissue. In conclusion, CT and DEXA measures of appendicular soft tissue are highly related. Systematic differences between DEXA and CT likely relate to the underlying principles of the techniques.
منابع مشابه
Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملValidity of fan-beam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass
MARJOLEIN VISSER,1,2 THOMAS FUERST,3 THOMAS LANG,3 LORAN SALAMONE,4 AND TAMARA B. HARRIS1 FOR THE HEALTH, AGING, AND BODY COMPOSITION STUDY— DUAL-ENERGY X-RAY ABSORPTIOMETRY AND BODY COMPOSITION WORKING GROUP 1Epidemiology, Demography and Biometry Program, National Institute on Aging, Bethesda, Maryland 20892; 2Institute for Research in Extramural Medicine, Faculty of Medicine, Vrije Universite...
متن کاملDual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population
Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملAssociations between pQCT-based fat and muscle area and density and DXA-based total and leg soft tissue mass in healthy women and men.
UNLABELLED Peripheral Quantitative Computed Tomography (pQCT) can be used for muscle and fat area and density assessments. These may independently influence muscle and fat mass measurements from Dual Energy X-ray Absorptiometry (DXA). OBJECTIVE To determine associations between pQCT-derived soft tissue density and area measures and DXA-derived soft tissue mass. METHODS Linear regression mod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 88 2 شماره
صفحات -
تاریخ انتشار 2000